6.3
SETUP
loop
In
this
loop
the
technician
can
configure
the
meter
via
the
front
keys.
This
enables
the
technician
to
configure
the
meter
both
before
installation
and
after
commissioning
of
the
meter.
Configuration
of
the
meter
after
commissioning
requires
that
the
installation
seal
is
broken
and
that
meter
top
is
separated
from
meter
base.
How
to
enter
SETUP
loop?
1.
In
general
(unless
otherwise
requested
by
the
customer)
SETUP
loop
is
available
when
the
meter
is
in
transport
state.
The
meter
leaves
transport
state
at
the
first
integration
or
if
SETUP
loop
is
ended
by
the
menu
point
”EndSetup”.
A
total
reset
of
the
meter
is
the
only
way
to
return
to
transport
state.
2.
When
the
meter
is
in
operation,
i.e.
the
meter
has
left
transport
state,
SETUP
loop
can
be
accessed
by
breaking
the
meter’s
installation
seal
and
separating
meter
top
from
meter
base.
How
to
end
SETUP
loop?
You
can
exit
SETUP
loop
in
three
ways.
All
three
ways
can
be
used
both
in
transport
state
and
after
commissioning
of
the
meter.
1.
Keep
the
primary
key
activated
and
navigate
to
the
meter’s
other
loops.
2.
After
4
minutes
the
meter
will
time
out
and
revert
to
the
first
reading
in
USER
loop.
3.
Navigate
to
the
menu
point
”EndSetup”
in
SETUP
loop
and
keep
the
secondary
key
activated
for
5
seconds.
Note:
This
locks
the
access
to
SETUP
loop,
and
thereby
the
meter
is
locked
against
further
configuration.
Subsequent
reconfiguration
of
the
meter
requires
that
you
break
the
installation
seal.
As
it
appears
from
the
table
overleaf
the
purpose
of
menu
point
”EndSetup”
is
to
enable
the
technician
to
lock
the
access
to
SETUP
loop
in
transport
state
and
thus
lock
the
meter
against
further
configuration.
This
function
is
e.g.
relevant
to
a
technician
who
knows
that
a
meter
is
to
be
mounted
in
the
installation
for
some
time
before
the
first
integration
will
be
carried
out
and
wants
to
lock
the
access
to
SETUP
loop
immediately
after
the
installation
to
make
sure
that
no
further
configuration
is
possible.
Please
note
that
it
is
only
possible
to
configure
the
meter
25
times
via
SETUP
loop.
After
25
times
the
meter
is
locked
against
further
configuration,
and
total
reset
and
reverification
of
the
meter
is
required
to
regain
access
to
SETUP
loop.
IMPORTANT:
EndSetup
is
an
important
function
when
the
meter
is
in
transport
state,
but
when
the
meter
is
in
operation,
EndSetup
is
just
one
of
three
ways
to
exit
SETUP
loop.