13.4
High
‐
resolution
volume
and
energy
High
‐
resolution
volume
and
energy
are
available
in
the
display
and
via
serial
communication.
See
below
table.
Function
Application
Value
Resolution
Display
Standing
start/stop
Volume
Energy
10
mL
1
Wh
Serially
–
from
latest
integration
Standing
start/stop
Volume
Energy
10
mL
1
Wh
Serially
–
interpolated
instantaneous
value
with
the
meter’s
time
stamp
Flying
start/stop
Volume
Energy
10
mL
1
Wh
Please
contact
Kamstrup
A/S
for
further
information
13.5
Temperature
calibration
The
temperature
measurement
is
adjusted
and
calibrated
during
the
production
process
and
it
does
not
require
further
adjustment
in
the
meter’s
lifetime.
The
temperature
circuit
can
only
be
adjusted
in
our
factory.
13.6
Pulse
interface
During
test
either
optical
reading
head
with
USB
plug
(6699
‐
099)
for
serial
reading
of
high
‐
resolution
energy
and
volume
registers,
or
Pulse
Interface
(6699
‐
143)
with
optical
reading
head
and
connection
unit
for
high
‐
resolution
pulse
outputs
is
used.
Do
not
forget
that
the
meter
must
be
in
test
mode.