Wired M-Bus • Water Meters flowIQ® 2101/3100 TECHNICAL DESCRIPTION
Kamstrup A/S · Technical Description · 55121944_A1_GB_08.2016
29
67h
01100111
Maximum ambient
temperature last month
°C
°C
E7h
11100111
Average ambient
temperature last month
°C
°C
6Ch
01101100
Target date
CP-16
Date
FFh
11111111
Info code register
FFh
11111111
Configuration number
FFh
11111111
Meter main and sub -type
FDh
11111101
Software revision
78h
01111000
Serial number
A-Type
Serial no.
79h
01111001
ID no.
A-Type
Meter no.
7Ah
01111010
Primary address
C-Type
Primary address
Note:
See EN13757-3 table 26 for a complete list of primary VIF’s and for the compound CP-16 format.
CODING:
VIF-field coding in the data package
SUBJECT:
Subject in the record
UNIT:
Unit required
SIZE:
Unit programmed in VIF
The M-Bus water meter uses information from the meter to place units, decimal points and number of decimals on
the values in the M-Bus telegram, ensuring that they correspond to the values read on the meter display, as far as
it is supported in the M-Bus protocol.
8.6
Special purpose VIF
Special purpose VIF codes used.
VIF (hex)
Coding
Description
Purpose
FDh
11111011
Second Extension of VIF codes
True VIF in first VIFE using Table 11 (EN13757-3)
FFh
11111111
Manufacturer specific extension VIFE’s and data following are manufacturer specific
Note:
See EN13757-3 table 27 for a complete list of special purpose VIF’s
8.7
Main VIFE-code extension
If primary VIF is 0FDh, a VIFE will follow. The following VIFE codes are used.
VIF (hex)
Coding
Description
Usage
0Eh
00001110
Metrology firmware version
Legal meter software revision
17h
00010111
Error flags (binary)
Meter Error (info) code (see section
Note:
See En13757-3 table 28, for a complete list of VIFE codes.