Kamstrup flowIQ 2101 Скачать руководство пользователя страница 17

Wired M-Bus • Water Meters flowIQ® 2101/3100                        TECHNICAL DESCRIPTION  

   

 

Kamstrup A/S · Technical Description · 55121944_A1_GB_08.2016 

17 

 

The datagram is fixed and cannot be changed. The datagram from flowIQ® 3100 large meter versions differs slightly 
from the one in flowIQ® 2101, because these large meters do not measure the water temperature. 

flowIQ® 2101 and flowIQ® 3100 1.6 and 2.5 and 4.0 m

3

/h 

M-Bus data header 

Actual data 

Monthly data 

Meter data 

M-Bus ID 
Manufacturer ID 

Version ID 
Device type 

Access counter 
Status (set if any info codes is 

active) 
Configuration (not used) 

Water meter reading (volume) 
Volume reverse 

Hour counter 
Actual flow 

Actual water temperature 
Actual ambient temperature  

Min Flow Day

1) 

Max Flow Day

1)

 

Min water temp Day

1)

 

Avg. water temp Day

1)

 

Min ambient temp Day

1)

 

Max ambient temp Day

1)

 

Avg. ambient temp Day

1)

 

Date/Time 

Monthly target meter reading 
Min Flow 1 Month 

Max Flow 1 Month 
Min water temp Month 

Avg. water temp Month 
Min Ambient temp Month 

Max Ambient temp Month 
Avg. Ambient temp Month 

Target date 
 

Information codes 
Config number  

Meter Type (main / sub type) 
Meter SW Revision 

 

flowIQ® 3100    Q3 = 6.3 m

3

/h and higher. 

M-Bus data header 

Actual data 

Monthly data 

Meter data 

M-Bus ID 
Manufacturer ID 

Version ID 
Device type 
Access counter 
Status (info codes) 

Configuration (not used) 

Water meter reading (volume) 
Volume reverse 

Hour counter 
Actual flow 

Actual ambient temperature  
Min Flow Day

1) 

Max Flow Day

1)

 

Min ambient temp Day

1)

 

Max ambient temp Day

1)

 

Avg. ambient temp Day

1)

 

Date/Time

 

Monthly target meter reading 
Min Flow 1 Month 

Max Flow 1 Month 
Min Ambient temp Month 

Max Ambient temp Month 
Avg. Ambient temp Month 

Target date 

 

Info 
Config number  

Meter Type (main / sub 
type) 
Meter SW Revision 
 

 

1)

 

The daily flow and temperatures are the actual daily minimum, average or maximum values logged from midnight 

until the present reading time.

 

6

 

Reading loggers from flowIQ® 2101/3100 wired M-Bus 

The loggers in the flowIQ® 2101/3100 can only be read with an optical reading head, the optical eye in the meter 
and the program LogView. 

7

 

Configuration of meter via the M-Bus network 

Following parameters can be sent to the M-Bus water meter, in order to change the configuration of the         
flowIQ® 2101/3100: 

 

Primary M-Bus address  

 

Date and time  

Selection of the M-Bus water meter via secondary address or enhanced secondary address, and application 

select/reset is obtained via SND_UD telegram from the M-Bus Master to the M-Bus water meter. Selection of 
device for secondary addressing is made by CI-field = 52h, and application select/reset by CI-field = 50h. 

Содержание flowIQ 2101

Страница 1: ...Technical Description Wired M Bus Water Meters flowIQ 2101 3100...

Страница 2: ...ation 6 5 2 Communication interval 6 5 3 Addressing forms 6 5 3 1 Primary addressing 7 5 3 2 Secondary addressing 8 5 3 3 Enhanced secondary addressing 9 5 3 4 Wildcard search with break detection 10...

Страница 3: ...3 Application select reset 19 8 Protocol 20 8 1 RSP_UD data flowIQ 2101 3100 data using Kamstrup specified VIFE 20 8 2 RSP_SKE response from flowIQ 2101 3100 25 8 3 Data header in RSP_UD 26 8 4 DIF Da...

Страница 4: ...it is possible only to transmit one way at a time on the M Bus The framing of the communication is 1 start bit 8 data bits 1 parity bit even and 1 stop bit The M Bus is communicating via voltage modu...

Страница 5: ...ng and future applications 3 1 1 Analysis The flowIQ 2101 3100 support high quantities of data and all relevant data for analysis can be read out This is valid for both actual meter data as well as fo...

Страница 6: ...re frequent reading is not recommended A more frequent reading interval than 32 seconds will provide redundant information 5 3 Addressing forms To make the M Bus system operate with more M Bus water m...

Страница 7: ...ia M Bus master In connection with primary addressing of the M Bus two or more M Bus water meters on the same M Bus system cannot have the same primary address However in connection with secondary add...

Страница 8: ...ual bytes with wildcard characters See chapter 5 3 4 for further information Selection of M Bus water meter via secondary address and deselecting other M Bus water meter Start character 68h L field 0B...

Страница 9: ...d via enhanced secondary address it will reply to primary address 253 as it is with the ordinary secondary addressing The M Bus water meter is deselected either by sending a new selection via primary...

Страница 10: ...y address may be replaced by the wildcard byte value FFh The values for DIF 0Ch for 4 bytes 8 digit BCD and VIF 78h for fabrication number in connection with enhanced secondary addressing cannot be re...

Страница 11: ...not returned The meaning of the CI Field CI FIELD 50h Application select reset Select is used for logger reading applications A reset will select the default application 51h Normal transmission of SND...

Страница 12: ...water meter only supports Mode 1 data format where all multi byte data values to and from the M Bus water meter are transmitted with Least Significant Byte LSB first In the default application the FC...

Страница 13: ...byte 1 xx Checksum xxh Stop character 16h 5 6 M Bus slave to M Bus master RSP_UD Long frame Data to M Bus Master See telegram later RSP_SKE Short frame Data to M Bus Master See telegram later ACK Sing...

Страница 14: ...a alarm protocol and using communication status bit SND_NKE ACK The M Bus Master normalizes the M Bus water meter with an SND_NKE and the M Bus water meter acknowledges successful receipt of the messa...

Страница 15: ...t 4 in the status field 5 7 1 Status field flowIQ 2101 3100 info codes are mapped to the error bit Temporary error bit 4 when any info code is active Further the Power Low bit 2 in the status field is...

Страница 16: ...o decode special data registers in an easier way Kamstrup has taken the approach to define a number of manufacturer VIF extensions so called VIFE The outcome is that most reading systems can show the...

Страница 17: ...ta Meter data M Bus ID Manufacturer ID Version ID Device type Access counter Status info codes Configuration not used Water meter reading volume Volume reverse Hour counter Actual flow Actual ambient...

Страница 18: ...quently 7 1 Setting Primary M Bus address A dedicated register in the flowIQ 2101 3100 is used for storing the primary address This register may be overwritten with a new M Bus primary address using t...

Страница 19: ...ord 04h DIF 4 bytes compound data type F Date and time 6Dh VIF Date and time e g 02 09 04 13 10 standard time valid Date time LSB 0Ah IV 0 MI5 MI4 MI3 MI2 MI1 MI0 Date time 2Dh SU HY1 HY0 H4 H3 H2 H1...

Страница 20: ...hown for a Version ID for flowIQ 2101 3100 water meter flowIQ 2101 flowIQ 3100 Byte Field Value Description 1 Start character 68h 2 L field 8Ah Length 138 bytes 3 L field 8Ah Length 138 bytes 4 Start...

Страница 21: ...e binary maximum value 54 VIF 3Bh Flow in l h 55 Max Flow 2Ah 298 l h 56 01h 57 DIF 21h 1 byte binary minimum value 58 VIF 5Bh Media temperature in C 59 Min Tmedia 05h 5 C 60 DIF 01h 1 byte binary 61...

Страница 22: ...um value 105 VIF 67h Ambient temperature in C 106 Min Tambient Month 10h 16 C 107 DIF 51h 1 byte binary monthly maximum value 108 VIF 67h Ambient temperature in C 109 Max Tambient Month 24h 36 C 110 D...

Страница 23: ...ld 72h 8 ID Number 78 BCD E g ID 12345678 9 56 BCD 10 34 BCD 11 12 BCD 12 Man ID 2Dh Manufacturer ID for Kamstrup A S KAM 13 2Ch 14 Version ID 1Dh Version ID for flowIQ3100 15 Device ID 16h E g 16h Co...

Страница 24: ...ent temperature 62 FFh 63 0Fh 64 Avg Tambient 1Ah 26 C 65 DIF 04h 4 byte binary 66 VIF 6Dh Type F Compound CP32 67 Date Time 02h E g CP32 23173782h 2017 03 23 23 02 68 37h 69 37h 70 23h 71 DIF 44h 4 b...

Страница 25: ...Eh 122 SW Revision 01h Software revision D1 123 04h 124 Checksum xxh 125 Stop Character 16h Note A target value may read as zero until passing the set target date 8 2 RSP_SKE response from flowIQ 2101...

Страница 26: ...00101101 C Manufacturer Id 2D ascii K 64 32 32 ascii A 64 32 MANUFACTURER 00101100 C Manufacturer Id 2C ascii M 64 ISO 60870 standard VERSION ID 1Fh 1Dh C M Bus version ID for flowIQ2101 M Bus version...

Страница 27: ...RATURES maximum daily 00010001 11h 8 bit binary Maximum Value Type B TEMPERATURES minimum monthly 01100001 61h 8 bit binary Minimum Monthly Value Type B TEMPERATURES average monthly 01000001 41h 8 bit...

Страница 28: ...h 00100010 Hour counter Hours Hours 3Bh 00111011 Flow l h m h 10 3 5Bh 01011011 Water temperature C C 67h 01100111 Ambient temperature C C 3Bh 00111011 Min flow since midnight l h m h 10 3 3Bh 0011101...

Страница 29: ...F The M Bus water meter uses information from the meter to place units decimal points and number of decimals on the values in the M Bus telegram ensuring that they correspond to the values read on the...

Страница 30: ...TECHNICAL DESCRIPTION Wired M Bus Water Meters flowIQ 2101 3100 30 Kamstrup A S Technical Description 55121944_A1_GB_08 2016 End of document...