Wired M-Bus • Water Meters flowIQ® 2101/3100 TECHNICAL DESCRIPTION
Kamstrup A/S · Technical Description · 55121944_A1_GB_08.2016
15
TAMPER: Meaning that the meter has been disassembled in an attempt of fraud.
The info code will disappear from the display and from the wired M-Bus datagram, when the condition that
initiated it disappears. Info codes initiate the Temporary error (bit 4) in the status field.
5.7.1
Status field
flowIQ® 2101/3100 info codes are mapped to the error bit ‘Temporary error’ (bit 4) when any info code is active.
Further, the ‘Power Low’ (bit 2) in the status field is set, when battery power is low.
The ‘Status field’ in the M-Bus data header can have one of the following values, or the sum of more values:
Status field value
Description
00h
No info code
04h
Power Low on battery
10h
Temporary Error
14h
Power Low and Temporary Error
5.7.2
Temporary error
Temporary Error (Bit 4) is set when one of the info codes is active in flowIQ® 2101/3100.