TECHNICAL DESCRIPTION Wired M-Bus • Water Meters flowIQ® 2101
/
3100
24
Kamstrup A/S · Technical Description · 55121944_A1_GB_08.2016
flowIQ® 3100:
Byte
Field
Value
Description
43
DIF
01h
1 byte binary
44
VIF
67h
Ambient temperature in °C
45
T
ambient
25h
37 °C
46
DIF
22h
2 byte binary, minimum value
47
VIF
3Bh
Flow in l/h
48
Min Flow
03h
3 l/h
49
00h
50
DIF
12h
2 byte binary, maximum value
51
VIF
3Bh
Flow in l/h
52
Max Flow
73h
371 l/h
53
01h
54
DIF
21h
1 byte binary, minimum value
55
VIF
67h
Ambient temperature in °C
56
Min T
ambient
0Eh
14 °C
57
DIF
11h
1 byte binary, maximum value
58
VIF
67h
Ambient temperature in °C
59
Max T
ambient
28h
40 °C
60
DIF
01h
1 byte binary
61
VIF
E7h
Kamstrup specific average ambient temperature
62
FFh
63
0Fh
64
Avg T
ambient
1Ah
26 °C
65
DIF
04h
4 byte binary
66
VIF
6Dh
Type F (Compound CP32)
67
Date/Time
02h
E.g. CP32: 23173782h = 2017-03-23 23:02
68
37h
69
37h
70
23h
71
DIF
44h
4 byte binary, monthly value
72
VIF
13h
Volume in m
3
with 3 decimals
73
V1 Target
A0h
66.976 m
3
74
05h
75
01h
76
00h
77
DIF
62h
2 byte binary, monthly minimum value
78
VIF
3Bh
Flow in l/h
79
Min Flow Month
03h
3 l/h
80
00h
81
DIF
52h
2 byte binary, monthly maximum value
82
VIF
3Bh
Flow in l/h
83
Max Flow Month
A9h
425 l/h
84
01h
85
DIF
61h
1 byte binary, monthly minimum value
86
VIF
67h
Ambient temperature in °C
87
Min T
ambient
Month
10h
16 °C
88
DIF
51h
1 byte binary, monthly maximum value
89
VIF
67h
Ambient temperature in °C
90
Max T
ambient
Month
24h
36 °C
91
DIF
41h
1 byte binary, monthly value
92
VIF
E7h
Kamstrup specific vif: average ambient temperature
93
FFh
94
0Fh
95
Avg T
ambient
Month
18h
24 °C