TECHNICAL DESCRIPTION Wired M-Bus • Water Meters flowIQ® 2101
/
3100
16
Kamstrup A/S · Technical Description · 55121944_A1_GB_08.2016
5.8
Datagram
The datagram in flowIQ® 2101/3100 M-Bus water meter has a fixed data content.
Previously, Kamstrup has placed a number of special registers like configuration values in the manufacturer
specified part of the telegram. This has required quite extensive knowledge of the meter in order to decode and
format these data correct.
In order to be able to decode special data registers in an easier way, Kamstrup has taken the approach to define a
number of manufacturer VIF extensions – so called VIFE. The outcome is that most reading systems can show the
special registers in clear reading.
Below an example showing manufacturer specified data vs. Manufacturer specified VIFE:
Manufacturer specified data
Special 10
00
00
00
5B
C9
A5
02
48
EE
00
00
E0
B2
03
00
0001x 66
19
6D
00
00
00
00
00
C1
00
01
07
08
70
01
06
0002x 00
00
00
00
00
Manufacturer specified VIFE
INT8
1234565000344
Inst
Manufacturer specific ->0F
INT4
34000
Inst
Manufacturer specific ->11
INT4
13301000
Inst
Manufacturer specific ->12
INT2
6145
Inst
Manufacturer specific ->1A