![background image](http://html1.mh-extra.com/html/kalfire/g-series/g-series_user-instructions_3272501013.webp)
13
2. 24 hour security
The appliance will stay in a blocked
position if no flame is detected after
three automatic ignition attempts
(error code 08A). The block will take
effect after one ignition attempt with
gas type G30. This block can twice be
unlocked manually with the remote
control. If no flame is detected after
two manual releases, the appliance
will remain blocked for 24 hours (a
‘lock-out’, code 08F). In that case,
you may not use the gas fire for
24 hours.
3. Overpressure protection
The gas fire is equipped with over-
pressure protection to minimise risk.
Should explosive ignition occur, the
glass panel on the front topside will
open to reduce the pressure.