flame intensity can also be displayed by 
the flame intensity indicator. 
The ECO mode has a modulating effect 
on flame intensity (higher or lower). 
This accentuates the visual effect 
and user comfort of the flames, while 
reducing the fire’s heat emission and 
gas consumption by approximately 
40%. Use the remote control to set the 
flame intensity in “ECO mode” to 9, 
after which the double flame icon  will 
display on the screen. Adjust the flame 
intensity as follows:

1.  Press +or ­to adjust flame intensity.
2.  Release the + or ­ button.
3.   Press  the  + button until the number 9 

appears to switch on the ECO mode.

4.7  Selecting the thermostat or 

manual operating programme

The flame intensity and the resulting 
room temperature can be adjusted by 
setting the remote control in manual or 
thermostat mode. To ensure an accura-
te temperature reading, make sure the 
remote control is outside of the fire’s 
radiation range. For security reasons, 
the thermostat mode will be automati-
cally switched off after 24 hours. If the 
flames in the gas fire have been swit-
ched off, the programme will restart in 
manual mode automatically when next 
switched on.

1.   By  pressing  P until the icon for 

 thermostat 

or manual mode

 

begin to flash.

2.  Press P again to selec the icon of 

your choice. 

3.  Briefly press

 to exit the menu.

3.   Walk around the appliance at a dis-

tance of 3 to 4 metres to measure 
the RFCK. If the RFCK shows a value 
of 4, the transmission strength of the 
remote control is good. If the value 
shows as 2 or 3, the RFCK values are 
acceptable. Transmission strength is 
insufficient at a RFCK value of 1.

4.  Confirm with 

to exit the menu.

4.5   Switching the appliance on and off

Carry out the following steps to turn 
the appliance on or off:

1.   Press 

 until the >OK< icon in the 

display appears and starts to flash.

2.   Continue to press 

and then press 

briefly on

to activate the ignition 

programme.

3.  Release both buttons.
   The word >WARM< will flash at the 

top left of the display as confirmati-
on of activation.

4.   Wait a number of seconds until you 

hear a beep and the word >WAIT< 
appears. The ignition programme will 
start and the burner will automati-
cally ignite after approximately  
20 seconds.

5.   Wait until you hear a second beep. 
   The word >WAIT< will stop flashing 

after the ignition programme.

6.   The gas fire flame is alight and ope-

rational.

7.   Press for approximately two seconds 

to extinguish the gas fire flame.

4.6  Setting the flame intensity

The height of the flames can be adjus-
ted from high to low and is indicated on 
the display by numbers 1 through 8. The 

Содержание G Series

Страница 1: ...User instructions BALANCED FLUE GAS FIRES DON T COMPROMISE EN...

Страница 2: ......

Страница 3: ...0 37S G160 41F G165 37C G170 37S for gas type G20 G25 and G30 Balanced flue gas fires Kalfire GP GP60 59F GP65 55C GP70 55S GP60 79F GP65 75C GP70 75S GP75 59F GP80 55C GP85 55S GP80 54T GP85 50R GP10...

Страница 4: ......

Страница 5: ...A Appendices 34 A 1 Product card 35 A 2 Wiring diagram 36 A 3 Certificate of compliance 37 Contents 1 General information 7 1 1 Foreword 7 1 2 Pictograms 8 1 3 Warranty 8 1 4 Compatibility iMatch int...

Страница 6: ...6...

Страница 7: ...the prior written per mission of Kalfire Kalfire reserves the right to make changes to the manual Kalfire however cannot provide any warranty implicitly or explicitly for this 1 General information Th...

Страница 8: ...uring transport storage or installation fall outside the scope of the warranty 7 Should disruption occur within the warranty period caused by a manu facturing error or material defect Kalfire will del...

Страница 9: ...one another including telephone tablet or router are incompatible The iMatch interface and your external sembly 8 Renewing or replacing components that fall under the scope of the gua rantee do not e...

Страница 10: ...equired With regard to the huge diversity of appliances their compati bility can regrettably not be confirmed beforehand Only after installation of the interface can compatibility be confirmed Kalfire...

Страница 11: ...e materials such as curtains and furniture are at least 100 cm from the fireplace If a fireguard is used this distance must be at least 40 cm 2 Safety The following sections provide safety information...

Страница 12: ...l be interrupted for one minute A new ignition attempt will follow automatically To interrupt au tomatic ignition attempts Press the button to switch off the fireplace directly and depress this button...

Страница 13: ...k can twice be unlocked manually with the remote control If no flame is detected after two manual releases the appliance will remain blocked for 24 hours a lock out code 08F In that case you may not u...

Страница 14: ...reduces gas use considerably If the house is equipped with a home automation system then operation of the appliance can be integrated 3 Description The following sections describe the gas fire Descrip...

Страница 15: ...that system The gas fire can also be controlled by the iMatch App on a smartphone or tablet This is only pos sible if the gas fire is equipped with the optional iMatch interface that serves as the re...

Страница 16: ...LED lighting 3 RF signal a flashing icon indicating that the appliance is beyond the re ach of the remote control 4 flame intensity indicator hybrid fire 4 Operation The upcoming sections provide inf...

Страница 17: ...ssing the centre button 5 To exit the parameters menu press P 6 Wait for 30 seconds while the infor mation is transmitted 4 4 Checking transmission strength Carry out the following steps in order to m...

Страница 18: ...thermostat or manual mode begin to flash 2 Press P again to selec the icon of your choice 3 Briefly press to exit the menu 3 Walk around the appliance at a dis tance of 3 to 4 metres to measure the R...

Страница 19: ...ments in this way should you not require all time segments these other segments should be set 4 8 Setting the flame intensity by thermostat The remote control measures the temperature and the flame in...

Страница 20: ...control indicate that the time seg ments have been programmed 4 10 Programme choice for the hybrid LED lighting If the gas fire is equipped with a hybrid LED lighting function it is possible to vary...

Страница 21: ...ore sparks there are The gas fire must be alight for some time before the Natural Spark Genera tor can produce sparks This is why the appliance only activates the Natural Spark Generator after it has...

Страница 22: ...erface 8 Click on the grey area to assign a name living room for example 9 Provide your local Wi Fi network s name and password Careful name and password are case sensitive 10 The iMatch interface mus...

Страница 23: ...onnected to your local Wi Fi network First install the iMatch app on your smartphone or tablet See Configure the iMatch app on page 21 Accessing home screen 1 Click on the iMatch app icon to open it 2...

Страница 24: ...ial causes can be Smoking materials in the fireplace especially in the beginning air conta mination quality of the type of gas etc Conditions Filth and stains on the glass must be removed immediately...

Страница 25: ...e avoid pressure and rub the substance from top to bot tom to prevent cleaning detergent to remain on the glass Continuously dry the glass comple tely using the cloth When using a vacuum lifter to rem...

Страница 26: ...door To put the door back in place follow the steps explained in step 3 in reverse order Lock the door by moving the handles down Twist the metal cover strips step 1 back into its original position by...

Страница 27: ...ock the door by moving the handles down Twist the metal cover strips step 3 back in its original posi tion by using the overlapping edge on the upper side of the strip and fold the metal cover strip d...

Страница 28: ...he waiting time must be respected also after a power interruption 5 2 Malfunctions Malfunctions can be organised in five categories 1 Permanent malfunctions indicated as F This malfunction cannot be f...

Страница 29: ...l stimulate the synchronisation speed Supply power back to the cable The entire light will start flashing once per second Should the gas fire is provided with a hybrid function and or NSG detach the H...

Страница 30: ...chnical unit does not flash 1 Check power supply on the mains 230VAC 2 If this is correct check replace the VDC transformer and or automatic burner relay In case the light on the automatic burner rela...

Страница 31: ...ply up to the technical box measure pre pressure 4 In the presence of pre pressure check whether the cables running from the automatic burner relay to the gas valve unit are damaged and or disconnecte...

Страница 32: ...cient voltage 1 Measure mains voltage 220VAC 2 Measure outgoing transformer voltage 24 VDC and 12 VDC 3 If the outgoing voltage is lower than 20 VDC or 10 VDC replace the transformer 4 If the outgoing...

Страница 33: ...erface technical unit or place a Wi Fi repeater You have not entered the Wi Fi settings orrectly in the app Check the Wi Fi settings Erase the added room from the app Reset the iMatch interface and tr...

Страница 34: ...34 A Appendices The following sections contain appendices attached to the gas fire Product card Wiring diagram Certificate of compliance...

Страница 35: ...C 10 8 kW n a 81 81 8 77 8 Kalfire G160 41F Kalfire G165 37C Kalfire G170 37S G30 30 mbar C 11 0 kW n a 79 83 8 77 0 Kalfire G160 41F Kalfire G165 37C Kalfire G170 37S G30 50 mbar C 11 3 kW n a 79 82...

Страница 36: ...36 A 2 Wiring diagram Wiring diagram Natural Spark Generator in the technical unit Fig 14 Wiring diagram HCB only applicable in hybrid mode and or Natural Spark Generator...

Страница 37: ...105 59F GP110 55C GP115 55S Kalfire GP105 79F GP110 75C GP115 75S Kalfire G60 48F G65 44C G70 44S G80 48F G85 55C G90 55S G100 41F Kalfire G105 37C G11037S G120 41F G125 37C G130 37S G160 41F G165 55C...

Страница 38: ...38...

Страница 39: ...39...

Страница 40: ...Gelo rveldweg 21 5951 DH Belfeld info kal fire nl KALFIRE COM DON T COMPROMISE REF V01 2019 EN...