+1.800.868.1699
13
KalamazooGourmet.com
12
Liquid Propane Gas Requirements
(30-Pound Cylinder)
Verify the type of gas your grill has been configured for by the factory by checking the serial
tag inside the door of the grill cabinet. Grills configured for liquid propane (LP) gas are orificed
differently than grills configured for natural gas (NG). Grills configured for use with 30-pound LP
cylinders (Type 1) are shipped with a dual-stage LP regulator hose assembly attached (see Figure 3).
Connection:
LP regulator hose assembly (included) connects to the grill via 0.5" NPT male with a
0.375" flare adapter (included).
Input Pressure via LP regulator hose assembly:
11” W.C.
Manifold Pressure:
10.5" W.C.
To connect the LP regulator hose assembly to the LP tank, first make sure the main valve on the tank
is completely closed. Make sure also that all control valves on the front of the grill are OFF.
Thread the regulator inlet over the tank valve. Use care to ensure proper alignment of the threaded
coupler and avoid cross-threading or damaging the coupler. Turn the green coupler clockwise until
tightened up, but do not over-tighten.
IMPORTANT:
Always close the main valve on the
tank before disconnecting or transporting the tank.
IMPORTANT:
After connecting a fresh LP tank,
you may need to purge air from the system. Before
lighting, open the main valve on the tank. Turn the
control valves on the grill to the HIGH position for
about 15 seconds to purge air from the system.
Turn the control valves on the grill OFF and wait 5
minutes for any gas to clear. Finally, continue with
the normal lighting procedure.
The installation must conform with local codes. In
the absence of local codes, the installation must
conform with the
National Fuel Gas Code, ANSI
Z223.1/NFPA 54; Storage and Handling of Liquefied
Petroleum Gases, ANSI/NFPA 58; Natural Gas and
Propane Installation Code, CSA B149.1;
or
Propane
Storage and Handling, CSA B149.2.
FIGURE 3 (Side Cabinet Model)
Bulk Gas Plumbing Information
IMPORTANT:
An installer-supplied safety shut-off valve MUST be installed at the gas supply line
connection point for the grill. The valve should be easily accessed and located between 3 and 20
feet away from the grill.
There is an onboard shut-off valve inside the grill for everyday convenience,
but the supply line shut-off valve is necessary for safety.
All gas connections should be made by a qualified technician. The installation and all installer-supplied
parts must conform to local codes. In the absence of local codes, the installation and all parts should
conform to the
National Fuel Gas Code, ANSI Z223.1/NFPA 54
or
Natural Gas and Propane Installation
Code, CSA B149.1.
Cooktops to be connected to a fixed fuel piping system must use rigid pipe, semi-
rigid tubing, and/or a connector that complies with the Standard for Connectors for Outdoor Gas
Appliances and Manufactured Homes, ANSI Z21.75/CSA 6.27.
IMPORTANT:
Always close gas supply shut-off valve before disconnecting the grill gas supply hose.
All pipe sealants must be an approved type.
IMPORTANT:
Diameter and length of the gas supply pipe may limit the pressure and BTU delivery of
gas to the grill. The installer must ensure proper delivery to the grill or it will not operate properly.
The appliance and its individual shut-off valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at pressures in excess of 1/2 psi
(3.5 kPa).
During any pressure testing of the gas
supply piping system at test pressures
equal to or less than 1/2 psi (3.5 kPa),
the appliance must be isolated from the
system by closing its onboard manual
shut-off valve.
Installer Supplied Shut-off
Valve at Connection
Factory-supplied
1/2" Gas Hose
Internal Regulator
3.5" WC NG
10.5" WC LP
FIGURE 4
(Built-In Model)
Main Tank Valve
30-pound LP Tank
Straps Secure Tank
to Tank Brace
2 Stage LP Regulator
Hose Assembly 11" WC
Regulator 8" WC
Regulator Connection
to Tank
Содержание K500HB-2-NA
Страница 6: ...1 800 868 1699 7 KalamazooGourmet com 6 Important Safety Information...
Страница 12: ...1 800 868 1699 19 KalamazooGourmet com 18 Product Dimensions...
Страница 16: ...1 800 868 1699 27 KalamazooGourmet com 26 Initial Assembly...
Страница 18: ...1 800 868 1699 31 KalamazooGourmet com 30 Operation...
Страница 27: ...1 800 868 1699 49 KalamazooGourmet com 48 Cooking Tips...
Страница 33: ...1 800 868 1699 61 KalamazooGourmet com 60 Recipes...
Страница 53: ...1 800 868 1699 101 KalamazooGourmet com 100 Product Care...
Страница 56: ...1 800 868 1699 107 KalamazooGourmet com 106 Electrical Diagrams...
Страница 59: ...1 800 868 1699 113 KalamazooGourmet com 112 Installation Checklist...
Страница 64: ......