![KAL-FIRE ECO-prestige 105-59 Скачать руководство пользователя страница 165](http://html1.mh-extra.com/html/kal-fire/eco-prestige-105-59/eco-prestige-105-59_installation-instructions-manual_650018165.webp)
61
control operations are tested. Following this, the fire is automatically set to ‘Off’
and remains in this state until it is manually set to ‘On’.
15.1
Troubleshooting solutions or restarting after a malfunction
The burner control’s automatic settings depend on which type of gas is used: natural gas
or propane/butane. In the case of natural gas, the burner will make 3 automatic ignition
attempts, while in the case of propane/butane, it makes only 1 attempt. If ignition fails,
the error code
A08
appears immediately and ‘
ER
’ (Error) displays at the top left of the
screen. Using the remote control (see section 15.2), 2 more ignition attempts can be
tried (or 1 attempt in the case of propane/butane). If this new attempt also fails, the
burner is automatically locked (error code
08F
).