SIMULATION TEST
35
⑥
Press SEL Key for 1 second or less in simulation
test mode to select RICH signal output or LEAN
signal output.
Do not apply the simulation test for titania 5V
O2 sensor to zirconia O2 sensor or titania 1V
O2 sensor. It may damage the O2 sensor and
ECU.
CAUTION
Do not take the simulation test for heater cable
or power supply cable during the electric car
components are activated. It may damage to
the instrument.
CAUTION
⑤
Press SEL Key for 1 second or more in stand-by
mode to enter simulation test mode. lights up
on LCD.
※
Confirm the selected O2 sensor type displayed
on LCD.
S
LEAN
RICH
Z
S
APO
Z
S
APO
④
Connect red and black check harness connecting
plugs to the red and black straight plugs
respectively.
Red test lead straight plug
Red check harness
connecting plug
Black test lead straight plug
Black check harness
connecting plug