![Kaise SK-8402 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/kaise/sk-8402/sk-8402_instruction-manual_649657016.webp)
SK-8402
取扱説明書(英文)
_P14
14
SPECIFICATIONS
●
Zirconia & Titania 1V
(sensor impedance : 100
Ω
or more at 23
℃
Typ)
※
Output following voltage by pressing TEST Key.
①
RICH mode : 0.8V Min. to 1.3V Max.
②
LEAN mode : approx. 0V
●
Titania 5V
(sensor impedance : 500
Ω
or more at 23
℃
Typ)
※
Output following voltage by pressing TEST Key.
①
RICH mode : 4.7V Min. to 5.3V Max.
②
LEAN mode : approx. 0V
4. Simulation Test (testing sign: TEST)
・
3 seconds signal output for each test.
・
3 seconds interval is necessary for each test. Continuous
testing is not possible.
・
Simulation test should be stopped and changed into stand-
by mode when battery voltage becomes 2.5V or less.
・
Simulation test mode is not activated when the battery
voltage becomes 2.5V or less.
・
Simulation test mode is not activated when the test
voltage in stand-by mode is lower than the threshold
("Err" display).
・
Simulation test mode is not activated when the test
voltage in stand-by mode is higher than the threshold
("H" display).
・
Simulation test is stopped and "OL" blinks on LCD when
the over current is detected.
OL (Over Load) : Warning indication of over current input
・
Sensor Impedance of detected threshold
・
Zirconia and Titania 1V sensor : sensor impedance
approx. 100
Ω
or less 23
℃
Typ
・
Titania 5V sensor : sensor impedance approx. 500
Ω
or
less 23
℃
Typ
・
The unit cannot be turned off during the simulation test.
●
LCD display
①
In RICH test : blinks.
②
In LEAN test : blinks.
RICH
LEAN
:
Lights up when Titania 5V sensor is selected
:
Lights up when simulation test mode is selected
:
Lights up or blinks when RICH voltage is displayed
or RICH voltage output is selected
:
Lights up or blinks when LEAN voltage is displayed
or LEAN voltage output is selected
:
Lights up when AVG voltage is displayed
:
Lights up when auto power off is activated
:
Lights up when cycle display mode is selected
:
Auxiliary unit in voltage display (mV)
:
Unit of voltage display
:
Test result is shown as bar graph (lighting or blinking)
:
Test result separator in bar graph
C
m
V
RICH
T5
S
AVG
LEAN
APO
Bargraph