25
NORMAL TEST
①
Connect red and black L-shaped plugs of the test
lead to red (
+
) and black (
−
) input terminals
respectively.
②
Press POWER Key for 1 second or more to turn on
the instrument. It enters stand-by mode for cable
connection check.
③
Press SEL Key for 1 second or less and select the
type of O2 sensor to be measured. Default setting
is zirconia O2 sensor.
※
LCD display might be drifting when connecting
the test leads or the cables due to the high input
impedance of this instrument, but does not affect
the measurement.
Check point
Titania O2 sensor always has power supply
cable (red). Confirm it when selecting.
Red test lead L-shaped plug
Black test lead L-shaped plug
mV
Z
APO
2. Measurement Procedure with
Check Harness