40
Suppose users set the “timer off” function and AC is off now, the AC will keep the current running mode
and then turn off when reaching the setting time.For 21k,24k models, the timer function will change the
AC current operation mode. Suppose users set the “timer off” function and AC is off now, the AC will
turn on firstly and then turn off when reaching the setting time.
8.4.7.7 The setting time is relative time.
8.4.8 Sleep function mode
8.4.8.1 Operation time in sleep mode is 7 hours. After 7 hours, the AC quits this mode and turns off.
8.4.8.2. Operation process in sleep mode is as follow:
After pressing ECONOMIC or SLEEP button on controller, the machine will turn into sleep mode.
When cooling, the setting temperature rises 1
℃(be lower th
setting temperature stops rising and indoor fan is fixed as low speed.
When heating, the setting temperature decreases 1
℃(be higher than 17℃) e
ur, 2 hours
later the setting temperature stops rising and indoor fan is fixed as low speed.(Anti-cold wind function
has the priority)
8.4.8.3 Timer setting is available.
8.4.8.4 When user uses timer off function in sleep mode(or sleep function in timer off mode), if the
timing is less than 7 hours, sleep function will be cancelled when reaching the setting time. If the timing
is more than 7 hours, the machine will not stop until reaches the setting time in sleep mode.
8.4.9 Auto-Restart function
The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart
module. In case of a sudden power failure, the module memorizes the setting conditions before the
power failure. The unit will resume the previous operation setting (not including Swing function)
automatically after 3 minutes when power returns.
If the memorization condition is forced cooling mode, the unit will run in cooling mode for 30 minutes
and then turn to drying mode
(
auto mode for 21k,24k models
)
as 24
℃ setting
temp.
8.4.10 Ionizer/Plasma dust collector function (optional)
The indoor unit is equipped with Ionizer, which is controlled by the CLEAN AIR button on the remote
controller. When the unit is turned on, press the CLEAN AIR button to activate the function. Press it
again to stop the function. During the time when Ionizer being controlled by remote controller, Ionizer
will be turned off automatically, if indoor fan stops running due to malfunctions or anti-cold-wind. When
Содержание R ON-OFF series
Страница 1: ...SPLIT WALL MOUNTED TYPE R ON OFF SERIES...
Страница 8: ...6 2 Function...
Страница 11: ...9 3 Dimension 3 1 Indoor Units Figure 1 Figure 2...
Страница 14: ...12 4 Refrigerant Cycle Diagram For heat pump models...
Страница 15: ...13 5 Wiring Diagram 5 1 Indoor Units KSR1 07HRN1 QC2 A KSR1 09HRN1 QC2 A KSR1 18HRN1 QB8...
Страница 16: ...14 KSR1 21HRN1 QB8W KSR1 21CR QB6W KSR1 21HR QB6W KSR1 24HRN1 QB8W...
Страница 17: ...15 5 2 Outdoor Units KOK1 07HN1 QC2 KOA1 09HN1 QC2...
Страница 18: ...16 KOE 18HN1 QB8...
Страница 19: ...17 KOF 21HN1 QB8W K0F2 21C QB6W KOP 21H QB6W...
Страница 20: ...18 KOF2 24HN1 QB8W...