50
EN
Install drainage pipe
Note:
Install drainage pipe before using, otherwise poor drainage will affect normal operation
of the unit.
1. Remove the rubber plug at drainage port.
2. Fix the drainage pipe clip on the right of rear side plate near drainage port with a screw.
3. Put the drainage pipe into drainage port and screw it up, and then bind it with pipe hoop.
4. Put the rubber plug into the other side of drainage pipe, fix it with pipe hoop and then fix
it in the drainage pipe clip.
rubber plug
drainage port
drainage port drainage pipe clip
screw
drainage port
pipe hoop
pipe hoop
rubber plug
drainage pipe clip
drainage pipe
Accessories and installation of heat
exhaust hose
● The length of the exhaust pipe is less than 1m. It is recommended to use it with shortest
● When installing, exhaust pipe should be as flat as possible. Don't prolong the pipe or
connect it with other exhaust pipe, or Correct installation is as shown in figure (When
length.
installing it on wall, height of hall should be about 40cm-100cm from floor).
Wrong installation is shown in following figure (If the pipe is bent too much, it would
easily cause malfunction.)
100cm
40cm