57
EN
Installation and disassembly of heat
discharge pipe
Disassemble heat discharge pipe
1. Remove joint B:
remove joint B from joint C.
joint B
joint C
joint A
upwards
clasp
2. Remove joint A:
Press the clasp and lift joint A upwards to
remove it.
disassemble
Operation test
●
Put through the power supply and then press ON/OFF button on remote controller to start
the unit.
●
Press mode button to select auto, cooling, drying, fan or heating function, and then check
●
If ambient temperature is below 16ºC, the unit can't operate in cooling mode.
if the unit operates normally.
Drainage way
spattered by water-striking motor. As the temperature of condenser is high, most of the
condensation water will be evaporated and drained to outdoor. So usually, only a little
condensation water will be accumulated inside the chassis and you do not need to
discharge the water frequently.
to remind user to discharge water:
horizontal during moving;
●
In cooling or drying operation, the condensation water will be drained to the chassis and
●
When the chassis is full with water, the buzzer will give out 8 sounds and "H8" is displayed
●
Move the unit to a suitable place for discharging water; do not tilt the unit and keep it
to discharge water;
●
Take the drainage pipe from the clip and pull out the rubber plug on the drainage pipe
fix the pipe on the clip;
●
Put back the rubber plug onto drainage pipe after finishing discharging water and then
minutes, the unit will resume operation.
●
After full water protection is eliminated and the compressor has been stopped for 3