MAINTENANCE

MAINTENANCE

Calibration

Routine maintenance of the Easidew is confined to regular re-calibration by exposure 

of the Easidew to sample gases of known moisture content to ensure that the stated 

accuracy of the Easidew is maintained.  Calibration services traceable to the 

National 

Institute of Standards and Technology (NIST) are provided by Kahn Instruments.

Kahn Instruments offers a variety of re-calibration and exchange sensor programs to 

suit specific needs. A Kahn representative can provide detailed, custom advice (for Kahn 

Instruments contact information go to www.kahn.com).

Sensor Guard Replacement

The sensor is supplied with a white HDPE guard (standard) or a stainless steel guard 

(if specified at time or order). The method of replacement is the same for both types.

HDPE Guard

The  HDPE  guard  provides  <10μm  protection  to  the  dew-point  sensor.  It  is  designed 

to show any contamination and the guard should be changed if the surface becomes 

discolored.
When replacing the guard, care should be taken to handle the guard by the bottom part 

only. Replacement guards (EA2-HDPE) - pack of 10 - can be obtained by contacting 

Kahn Instruments (www.kahn.com).

          

 Ea

sid

ew

 34

 T

ra

ns

m

it

te

r

          

      

    

    

    

   

   

   

   

09

06

          

      R

ang

e: 

- 1

00

 / 

+2

0

                

      

     

 

  4

8 L

an

ca

st

er

 W

ay

 B

                

      

     

 

    

   

El

y, 

Ca

m

br

id

ge

s

                

      

     

 

    

   

   

   

   

   

 C

B

3N

                

      

     

 

    

   

   

   

Un

ite

K

in

g

                

     

 

     

  

M

IC

H

E

                 

     

     

    

   

 

In

st

ru

m

en

HANDLE, 

USING

GLOVES, BY 

BLACK PART

ONLY

Figure 11 

Replacement of HDPE Guard

Stainless Steel Guard

The  stainless  steel  guard  provides  <80μm  protection  to  the  dew-point  sensor.  It  is 

designed to show any contamination and the guard should be changed if the surface 

becomes discolored.
When replacing the guard, care should be taken to handle the guard by the bottom 

part only. A replacement guard (SSG) can be obtained by contacting Kahn Instruments 

(www.kahn.com).

Bonded Seal

If the installed bonded seal gets damaged or lost, a pack of 5 replacement bonded seals 

can be obtained by contacting Kahn Instruments, and quoting part number BS-58-PK5. 

Содержание Easidew

Страница 1: ...2 0 Kahn Instruments Inc 2015 This document is the property of Kahn Instruments and may not either in part or whole be copied or otherwise reproduced communicated in any way to third parties nor store...

Страница 2: ...tional 6 2 5 2 Transmitter Mounting Direct Pipeline Connection 7 3 OPERATION 8 4 MAINTENANCE 9 Figures Figure 1 Transmitter Unpacking Method 2 Figure 2 Connector Terminal Block Removal 3 Figure 3 Wiri...

Страница 3: ...tain the equipment in a safe condition The safety instructions are either warnings or cautions issued to protect the user and the equipment from injury or damage Use competent personnel using good eng...

Страница 4: ...egapascal Nl min normal liters per minute Nm Newton meter oz ounces ppmV parts per million by volume psig pounds per square inch RH relative humidity scfh standard cubic feet per hour scfs standard cu...

Страница 5: ...ahn representative for Kahn Instruments contact information go to www kahn com 1 1 Features The Easidew dew point transmitter is a continuous on line 4 20mA transmitter for the measurement of moisture...

Страница 6: ...move the foam block 3 containing the connector 2 3 Pull out the transmitter 5 from the tube complete with the two foam covers 6 and 7 and the red protective cap 4 4 Remove the foam covers from the tra...

Страница 7: ...tained on the screw and are present during re installation For the transmitter to work properly and to achieve maximum performance the sensor cable must be connected to the sensor connector as shown i...

Страница 8: ...the O ring and washer must be tightened to a minimum torque setting of 2 5 ft lbs 3 4 Nm The sensor cable used must be a minimum diameter of 0 2 4 6mm Figure 4 Connector Installation 2 4 Electrical Sc...

Страница 9: ...ounted into either a flow through sensor sampling block optional or directly inserted into a pipe or duct and can be operated at pressures of up to 5000 psig when installed with the bonded seal provid...

Страница 10: ...been removed from the tip of the transmitter 2 Install the bonded seal 4 over the threaded part of the transmitter body WARNING Under no circumstances should the sensor guard be handled with the fing...

Страница 11: ...integrity of a gas tight seal a mounting flange will be required on the pipe in order to provide a flat surface to seal against The following procedure must be carried out by competent personnel 1 Ins...

Страница 12: ...ty can damage the sensing element and similarly at low velocity they may blind the sensing element and reduce its response speed If particulate such as degraded desiccant pipe scale or rust is present...

Страница 13: ...dew point sensor It is designed to show any contamination and the guard should be changed if the surface becomes discolored When replacing the guard care should be taken to handle the guard by the bot...

Страница 14: ...Easidew Transmitter User s Manual 10 Issue 9 1 December 2012 APPENDIX A Appendix A Technical Specifications...

Страница 15: ...ting Temperature 40 to 140 F 40 to 60 C Operating Pressure 5000 psig max Flow Rate 2 to 10 scfh 1 to 5 Nl min mounted in standard sampling block 0 to 33 fps 0 to 10 m sec direct insertion Temperature...

Страница 16: ...User s Manual 12 Issue 9 1 December 2012 APPENDIX A Dimensions 27mm 1 06 A F 45mm 1 77 132mm 5 19 46mm 1 81 10mm 0 39 10mm 0 39 27mm 1 06 5 8 18 UNF 5 8 Bonded Seal Sensor 25 4 x 2mm 1 x 0 07 Figure 1...

Страница 17: ...Easidew Transmitter User s Manual Kahn Instruments 13 APPENDIX B Appendix B UL Certification Listing Number E331965 Standards UL61010 1 2nd Edition CAN CSA C22 2 No UL61010 1 2nd Edition...

Страница 18: ...Easidew Transmitter User s Manual 14 Issue 9 1 December 2012 APPENDIX C Appendix C EC Declaraton of Conformity...

Страница 19: ...Easidew Transmitter User s Manual Kahn Instruments 15 APPENDIX C Appendix C EC Declaration of Conformity...

Страница 20: ...http www kahn com...

Отзывы: