Easidew Transmitter User’s Manual
4
Issue 9.1 December 2012
INSTALLATION
2.3
Cable Connection
When installing the connector, and to insure that full ingress protection is achieved, the
retaining screw (with the O-ring and washer) must be tightened to a minimum torque
setting of 2.5 ft-lbs (3.4 Nm). The sensor cable used must be a minimum diameter of
0.2” (4.6mm).
Figure 4
Connector Installation
2.4
Electrical Schematic
NOTE: The screen/shield should be connected for maximum performance
and to avoid interference.
3
1
Max Load
250R @ 12V
500R @ 24V
Supply
12V Min
28V Max
+
Screen/
Shield
Figure 5
2-Wire Connection Diagram