GENERAL SAFETY INFORMATION

1. 

PRESSURIZED DEVICES:

This equipment is a pressure containing 

device.
•  Do not exceed maximum operating 

pressure as shown on equipment 

serial number tag.

•  Make sure equipment is depressurized before 

working on or disassembling it for service.

2. ELECTRICAL:

This equipment requires electricity to 

operate.
•  Install equipment in compliance with 

all applicable electrical codes.

•  Standard equipment is supplied with electrical 

enclosures not intended for installation in hazardous 

environments.

•  Disconnect power supply to equipment when 

performing any electrical service work.

3. 

BREATHING AIR:

•  Air treated by this equipment may 

not be suitable for breathing without 

further purification.

 

Refer to applicable standards and 

specifications for the requirements for breathing 

quality air.

RECEIVING, MOVING, AND UNPACKING

A. RECEIVING

This shipment has been thoroughly checked, packed and 

inspected before leaving our plant.  It was received in 

good condition by the carrier and was so acknowledged.
Check for Visible Loss or Damage.  If this shipment shows 

evidence of loss or damage at time of delivery to you, 

insist that a notation of this loss or damage be made on 

the delivery receipt by the carrier’s agent.

B. UNPACKING

Check for Concealed Loss or Damage.  When a shipment 

has been delivered to you in apparent good order, but 

concealed damage is found upon unpacking, notify the 

carrier immediately and insist on his agent inspecting 

the shipment.  Concealed damage claims are not our 

responsibility as our terms are F.O.B. point of shipment.

C. MOVING

In moving or transporting dryer, do not tip dryer onto its 

side.

D. 

STORAGE/SHUT DOWN

   Dryer should not be stored outside (either 

packed or unpacked) or exposed to the weather.  Damage to 

electrical and control components may result.
IMPORTANT:  WATER-COOLED UNITS - If unit is shut down 

below freezing temperatures, the water-cooled condenser 

may freeze and cause permanent damage.  Condenser must 

be drained when the unit is shut down.
IMPORTANT:  Do not store dryer in temperatures above 130°F 

(54.4°C).

Содержание TF 171E

Страница 1: ...NG 2 1 0 INSTALLATION 3 2 0 OPERATION 5 3 0 MAINTENANCE 8 SIZING 8 ENGINEERING DATA 9 WIRING DIAGRAM Model TF 171E 10 11 Model TF 210E 12 13 575 460 3 60 Transformer Pack 14 DIMENSIONS WEIGHTS 15 TROU...

Страница 2: ...our plant It was received in good condition by the carrier and was so acknowledged Check for Visible Loss or Damage If this shipment shows evidence of loss or damage at time of delivery to you insist...

Страница 3: ...d 45 to 130 F 7 to 54 C E Installations in altitudes above 4500 feet 1370 meters Dryer is adjusted to operate in altitudes up to 4500 feet 1370 meters If dryer is installed in an altitude above this a...

Страница 4: ...manual draining convenient dryer depressurization and EDD service a three way valve assembly has been installed at the bottom of the moisture separator and cold coalescing filter where applicable Rev...

Страница 5: ...the pilot air supply line and opening the pilot air exhaust line After the pilot air above the diaphragm 4 is vented pressure in the reservoir opens the discharge port and forces the condensate throug...

Страница 6: ...m on or off use On Off button Push Schedule On Off and Enter button to return to schedule NOTE After power interruption dryer will reenergize in Manual override refrigeration system off To restart Sch...

Страница 7: ...contact on the compressor contactor is open when the dryer is off TEMP SENSOR Occurs if the temperature sensor circuit is open or shorted If open the left most LED in the temperature display will be i...

Страница 8: ...tiply the rated capacity from Table 1 by the multipliers shown in Table 2 Example How many scfm can an air cooled model TF 171E handle when compressed air to be dried is at 200 psig and 100 F ambient...

Страница 9: ...psig 9 3 barg Required Available Water Pressure Differential 40 psig 2 8 barg minimum Flow Required with 85 F Cooling Water gallons per minute 60 Hz 4 9 6 8 50 Hz 4 1 5 6 Electrical Data Nominal Volta...

Страница 10: ...only FAN 2 HARNESS FPS 2 FAN 2 REF SHEET 02 LINE 11 REF SHEET 02 LINE 10 REF SHEET 01 LINE 20 03 10 11 12 09 08 07 06 05 04 L3 L3 L3 L2 L2 02 01 00 PE TB1 L1 L2 L3 L1 L1 L1 L2 L3 CONT 1 PE TB2 T1 T2 T...

Страница 11: ...5 W13 W14 W11 W10 W9 W8 W21 W19 Alarm B N C Alarm B Com Drain Test Output Alarm B N O Drain Test Output Compressor 1 Output Compressor 1 Output W27 W18 W17 W16 N A N A W25 W23 FROM SHEET 01 01 03 02 0...

Страница 12: ...HEATER 1 FAN 2 HARNESS FPS 2 FAN 2 REF SHEET 02 LINE 11 REF SHEET 02 LINE 10 REF SHEET 01 LINE 20 03 10 11 12 09 08 07 06 05 04 L3 L3 L3 L2 L2 02 01 00 PE L1 L1 L1 L2 L3 TB1 L1 L3 L2 CONT 1 DISCONNECT...

Страница 13: ...5 W13 W14 W11 W10 W9 W8 W21 W19 Alarm B N C Alarm B Com Drain Test Output Alarm B N O Drain Test Output Compressor 1 Output Compressor 1 Output W27 W18 W17 W16 N A N A W25 W23 FROM SHEET 01 01 03 02 0...

Страница 14: ...14 WIRING DIAGRAM 575 460 3 60 Transformer Pack...

Страница 15: ...25mm ELECTRICAL ENTRY 750 19mm RS 232 ACCESS 0 25 NPT DRAIN CONNECTION MODEL TF171E 0 25 NPT DRAIN CONNECTION MODEL TF210E Dimensions inches mm Model TF 171E TF 210E A 58 06 1475 58 06 1475 B 32 15 81...

Страница 16: ...enser cooling Air cooled Ambient temperature too high clogged condenser fins obstructed flow across condenser faulty fan motor or fan control switch Water cooled Cooling temperature too high flow too...

Страница 17: ...30763 Hot Gas By Pass Valve Air Cooled 5002351 5002351 5002351 5002351 Filter Dryer Liquid Line 5002925 5002925 5002925 5002925 Temperature Sensor 3210926 3210926 3210926 3210926 Contactor 5002926 500...

Страница 18: ...18 NOTES...

Страница 19: ...19...

Страница 20: ...price of the product or part THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR STATUTORY AND IS EXPRESSLY IN LIEU OF THE IMPLIED WARRANTY OF MERCHANTABIL...

Отзывы: