Initial Start
7 --- 22
7
Putting into Operation
7.1
Points to be Observed before Putting into Operation
Every compressor package is given a test run at the factory and carefully inspected before
shipment. The test run confirms that the package conforms to the specification data and
runs perfectly. However, the compressor package could be damaged during transport. For
this reason, we recommend that the package be examined for possible shipping damage.
It is recommended that an operator observe the compressor package carefully during the
first hours of operation for any possible malfunction.
Important functional components in the compressor package (such as
minimum pressure check valve, safety relief valve, inlet valve and com-
bination valve) are adjusted and fitted to factory standards and specifi-
cations. Alterations to these components are not allowed without prior
written authorization with the manufacturer.
Do not disassemble the minimum pressure check valve, safety relief
valve and inlet valve. They are heavily spring loaded.
Disassembly by unqualifed personnel may result in personal injury or
equipment damage.
7.2
Points to be Observed before Starting the Compressor Unit
ANY NON -- OBSERVANCE OF THIS OR OTHER REFERENCES (WARN-
ING; ATTENTION; DANGER ) CAN LEAD TO ACCIDENTS CAUSING IN-
JURY TO PERSONS OR DAMAGE TO EQUIPMENT.
If a power failure occurs, the compressor package starts again auto-
matically (normal setting) provided the line pressure is lower than the
pressure threshold parameter entered in SIGMA CONTROL.
Do not operate the compressor with open maintenance doors or with
cover panels removed as personnel could be injured by rotating parts
and electrical equipment.
Remove all packaging materials, tools and transport securing devices on and in the
compressor package.
-
The operator is expected to practice safe working techniques and to follow all recom-
mended operating and safety regulations when operating this compressor package.
-
The operator of this compressor unit is responsible for its safe operating condition.
-
Do not operate this compressor unit in locations where high dust conditions, poison-
ous, or inflammable gases could exist.
-
Do not connect the compressor package to a supply voltage other than that stated on
the nameplate.
-
Do not install the compressor package in a location subject to freezing temperatures.
The air temperature requirements at the air intake must be complied with (see
chapter 1.6).
-
If exhaust air ducts are to be installed the duct cross section must be equal or larger
than the cooling air outlet of the compressor package and may not exceed the per-
mitted pressure loss prescribed by the compressor manufacturer.
Attention!
Содержание CSD 75
Страница 2: ......
Страница 11: ...Technical Specification 1 6...
Страница 19: ...Construction and Operation 5 14...
Страница 20: ...Construction and Operation 5 15...
Страница 58: ...Appendix 11 53 11 Appendix 11 1 Wiring Diagram...
Страница 59: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 70: ......
Страница 71: ......
Страница 72: ......
Страница 73: ......
Страница 74: ......
Страница 75: ......
Страница 76: ......
Страница 77: ...Appendix 11 72 11 2 Maintenance Schedule Model No Serial No Date Description of work Operating hours Signature...