Fig. 2 Logger, rear view
1
Power supply unit port
2
Address field with rotary controls
3
Rotary control for setting the logger ad‐
dress
4
Internal memory card
5
USB port
6
Network port (Ethernet/PoE)
Power supply unit port
The power supply unit from the basic measuring kit is connected to the 24 V port
1
to provide cur‐
rent to the logger.
Address field
The logger's address field
2
provides the following setting options:
■ 2 rotary controls
3
to be set to a value between 0 and 9.
■ A number circle mapping the setting positions for the possible values of the rotary controls.
The two set values together create the logger's address.
Example:
The left rotary control is set to 3 and the right one is set to 7, giving the logger the address 37.
The address of every connected logger must be unique for the duration of a measurement.
Memory card
The bay to the right of the address field
4
contains an internal memory card storing the measured
values during the measurement.
This memory card is exclusively designed for this function, and can never be replaced by another
memory card not specifically designed for this function.
➤ Never try to replace a defective memory card.
➤ Please contact the authorised KAESER Service if the memory card in your logger is defective.
4
Design and Function
4.3
The logger
No.: 901711 00 E
Operating manual measuring and analysis system
ADA 2 EFFICIENCY OPTIMIZATION
7