Fig. 1 Basic measuring kit: Hardware
1
Logger (2x)
2
Signal converter with 2 digital channels
(4x)
3
Power supply unit (2x)
4
Connector cable (4x)
5
Pressure transducer (4x)
One signal converter can acquire the values from two digital channels and convert them to analog
signals.
The most common applications are the measurement of the "LOAD/IDLE" and "Motor On/Motor
Off" status pairs.
Use a connector cable to create the connection of a signal converter from the machine's measuring
point to a logger.
Pressure transducers are used to measure the pressure at the desired locations within a com‐
pressed air station.
Although not visible, the basic measuring kit also contains four adapters for measuring devi‐
ces that can be provided in special accessory kits. Specific accessories are necessary for all
measurements that cannot be taken with pressure transducers or signal converters (see Ta‐
4.3 The logger
Measuring data are captured by and recorded on a logger of the ADA 2 measuring and analysis
system.
When measuring with a single logger, this logger is directly connected to the notebook which is
used to access the ADA 2 user interface, and with the compressed air station for which measured
values are to be captured.
4
Design and Function
4.3
The logger
6
Operating manual measuring and analysis system
ADA 2 EFFICIENCY OPTIMIZATION
No.: 901711 00 E