![Kaco Powador 7700 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/kaco/powador-7700/powador-7700_operating-instructions-manual_3566397030.webp)
Configuration and Operation
Page 30
Operating Instructions for Powador 7700-9600_EN
EN
EN
8
Configuration and Operation
8.1
Controls
The inverter has a backlit LCD as well as three status LEDs. The inverter is operated using two buttons.
1
2
3
!
ok
Figure 23: LED indicators
Key
1
"Operating" LED
2
“Feed-in” LED
3
"Fault" LED
8.1.1 LED indicators
The three LEDs on the front of the inverter show the different operating states. The LEDs can display the following
states:
LED illuminated
LED flashing
LED not illuminated
Operating status
LEDs
Display
Description
Start
ok
The green “Operating” LED is on when AC voltage is
present, independent of the DC voltage.
Feed-in start
ok
Power fed into the
grid
or measured
values
The green "Operating" LED is lit.
The green "Feed-in" LED is illuminated after the coun-
try-specific waiting period*.
The inverter is ready to feed in, i.e. is on the grid.
You can hear the grid relay switch on.
Feed-in start
ok
Power fed into the
grid
or measured
values
The green "Operating" LED is lit.
The green "Grid feed" LED is illuminated after the coun-
try-specific waiting period*.
The inverter is internally power-reduced and ready to
feed in, i.e. is on the grid. (as per VDE-AR-N-4105)
Alternatives
1. Internal/external power limiting or start-up limiting
is active
2. The inverter is operating in standalone mode
Non-grid feed mode
ok
Status message
The display shows the corresponding message.
* The waiting period ensures that the generator voltage continuously remains above the power delivery limit of
200 V.