STATES OF THE LOCK

Factory Mode

The factory mode is one of three primary states of the E-Plex 2000 and the E-Plex

PowerStar 2000. The main characteristics of this state are:

• The E2000/EPS2000 opens only when the 8-digit master combination (1-2-

3-4-5-6-7-8) is keyed in. 

• The visual indication for ‘access granted’ is green LED flashing once.  A

high-pitched tone is also generated while the green LED is on.

• The Master User must change the combination to be able to exit the 

factory mode, and switch to the access mode.

Access Mode

This mode refers to a lock that is operational for user access, and not in 

factory or Programming Mode.

Pushbutton Programming Mode

The lock enters the Pushbutton Programming Mode when the user enters the

master combination or one of the manager combinations, preceded and fol-

lowed by the character ‘#’ (ex: #12345678#). Once the E-Plex 2000 is in the

Pushbutton Programming Mode, the Master/Manager can enter one or more

command sequences. Each command sequence ends with a ‘#’ character that

acts like an <

enter

> character.  At the very end of all sequences of program-

ming commands, enter one more # to remove the lock from the Pushbutton

Programming Mode to return to normal access mode.

SEQUENCE OF OPERATIONS 
FOR START-UP PROGRAMMING

What is the recommended sequence of operations?

With the E-Plex 2000/EPS2000 in the factory mode.

• Program the Access Code Length (default length is four digits).

The access code field length can only be changed when the 

lock is not activated (when still in the factory mode).

• Change factory Master to your own Master Code (always eight digits) to

place lock in access mode.

Put lock in Pushbutton Programming Mode.

• Program the Unlock time.

• Program the Lock for the Duration of Passage Mode (if desired).

• Program the Lock for Tamper Time Settings.

• Program the Lock for Buzzer Volume.

• Add Access Codes as desired.

Содержание E-PLEX 2000

Страница 1: ...Operations Manual E PLEX 2000 Series E PLEX PowerStar 2000 Series...

Страница 2: ...Program the Duration of the Passage Mode Period 10 E Program the Lock for Tamper Time Parameters 11 F Programming the Lock for Keypad Buzzer Volume 11 Users General Information 12 User Levels 12 User...

Страница 3: ...s 23 Visual Feedback Message Definitions 26 User List Table 27 TABLE OF CONTENTS continued A publication of Kaba Access Control 2941 Indiana Avenue Winston Salem NC 27105 No part of this book may be r...

Страница 4: ...This energizes the lock temporarily for a few seconds enough time for you to enter your PIN and open the lock or start to program the lock with a command sequence Typically you will need to pump the...

Страница 5: ...mming If you do not pump the handle there will be no response from the lock and consequently there will be no access granted You must instruct your EPS 2000 series lock door users on how to use this l...

Страница 6: ...ter ex 12345678 Once the E Plex 2000 is in the Pushbutton Programming Mode the Master Manager can enter one or more command sequences Each command sequence ends with a character that acts like an ente...

Страница 7: ...e pages that follow provide step by step instructions for programming the E Plex 2000 EPS2000 lock 2 The general procedure for all programming functions is as follows a Put the lock in Programming Mod...

Страница 8: ...recommended that the master user code not be used for every day access This can be accomplished by creating an access user code for the master user Reset Procedures There are three different Reset le...

Страница 9: ...g the procedure in on page 7 A 3 Enter the code 009 LL where LL represents the length number of digits in a code The range is from 04 to 08 digits You can leave the factory default Access Code length...

Страница 10: ...the lock remains in Passage Mode is programmable on all models except EPS2000 PowerStar versions The factory default length of time for Passage Mode is 9 hours you may leave the default Once the lock...

Страница 11: ...the code as follows 007 TT TT is number of wrong entries 03 to 09 let s use 03 for example a Example of Complete Entry 007 03 b Enter another to indicate the end of programming c The lock will stay lo...

Страница 12: ...rors during a command sequence If an invalid entry occurs recover from the mistake by entering the key which will clear all entries made from the beginning of the current command sequence and will res...

Страница 13: ...or you must program the door with an Access Code for them This User Access Code can also be referred to as a PIN Personal Identification Number If you modify the Access Code for an existing user the p...

Страница 14: ...foreign part If the lock is used with a wall bumper the warranty is null and void If a doorstop is required we recommend the use of a floor secured stop The environment and conditions of use determine...

Страница 15: ...CONTROL 2941 INDIANA AVENUE WINSTON SALEM NC 27199 3770 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS MAIL PERMIT NO 1563 POSTAGE WILL BE PAID BY ADDRESSEE WINST...

Страница 16: ...se Room This lock is o Replacing a conventional o Replacing a Simplex Unican Kaba Ilco Kaba Access keyed lock Control Mechanical Pushbutton Lock e g L1000 o Replacing another electronic keyless lock H...

Страница 17: ...senting a User Access Code of between 4 and 8 numbers depending on the length of Access Code that you selected in Procedure 1 on page 7 For example if your code length is 4 digits the number could be...

Страница 18: ...ramming Mode I 2 Enter Command 102 to add modify a Service User Access Code I 3 Enter the Service User ID location a three digit number you have on a list that you should carry with you followed by fo...

Страница 19: ...nager Codes that might be needed some time in the future should be de activated rather than deleted Required User Level Master K 1 Put the lock into Pushbutton Programming Mode K 2 Enter Command 201 t...

Страница 20: ...er another to indicate the end of programming M 4 You have now deleted all User Access Codes allowing you to re assign Access Codes from 0000 0000 to 9999 9999 if not used by Master or Managers N ACTI...

Страница 21: ...during a Service User s vacation for example or if you created an Access Code but never assigned it to a Service User Required User Level Master Manager P 1 Put the lock into Pushbutton Programming M...

Страница 22: ...e R 4 Example of Complete Entry to activate Passage Mode 399 1 R 5 Enter another to indicate the end of programming R 6 You have now activated Passage Mode on the door S DE ACTIVATE USER ACCESS CODES...

Страница 23: ...User Level Master Manager U 1 Put the lock into Pushbutton Programming Mode U 2 Enter Command 402 to de activate a Service User Access Code U 3 Enter the code 402 NNN where NNN is the specific Manage...

Страница 24: ...zer and the twelve pushbuttons 0 through 9 and Required User Level Master X 1 Put the lock into Pushbutton Programming Mode X 2 Enter Command 500 for Diagnostics X 3 You will see a green LED and hear...

Страница 25: ...ramming Commands Name Configure Command 000 MMMMMMMM MMMMMMMM 004 TT 005 TT 006 TT 007 TT 008 VV 009 LL 099 Description of Command Modify Master User Access Code lock s activation Always 8 digits Unlo...

Страница 26: ...ify Manager Access Code NNN specific User ID location 001 to 099 Combination length can be 4 to 8 digits depending on access length LL setting Add Modify Service User Access Code NNN specific User ID...

Страница 27: ...Master and Manager Activate De Activate Passage Mode P 0 or 1 0 disable Passage Mode 1 enable Passage Mode De Activate User Access Code NNN specific User ID location 001 to 099 De Activate Manager Acc...

Страница 28: ...Access denied OFF ON 1 sec A Once B Valid programming ON OFF 1 sec Once entry Invalid programming OFF ON 1 sec A Once B entry including duplicate access code Tamper shutdown OFF ON 2 sec Once beginni...

Страница 29: ...27 E Plex 2000 User List Table User Access Code User Name User Type 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 099...

Страница 30: ...28 Notes...

Страница 31: ...29 Notes...

Страница 32: ...Kaba Access Control 2941 Indiana Avenue Winston Salem NC 27105 USA Tel 800 849 8324 336 725 1331 Fax 800 346 9640 336 725 3269 www kabaaccess com PKG3173 0311...

Отзывы: