INTRODUCTION
The E-Plex 2000 (E2000) and the E-Plex PowerStar 2000
(EPS2000) are both easy to use PIN only lock series that do
not require any software to operate.
E2000 Operation
The E2000 uses three (3) AA alkaline batteries. This means that
anytime you can simply access the lock with your valid PIN and/or
you can program the lock at its keypad since the lock power is
always present for its electronic circuit to operate.
EPS2000 Operation
The EPS2000 Self Powered Lock does not contain any batteries
and is environmentally friendly (“Green” lock). The lock electronics
are always “asleep” but to activate the circuit to access and/or pro-
gram the lock, you must power the lock by depressing the front
lock lever down at least once. This energizes the lock temporarily
for a few seconds, enough time for you to enter your PIN and open
the lock, or start to program the lock with a command sequence.
Typically, you will need to pump the lock lever only once whenever
you need to access the lock, or to start programming the lock.
However, if you had not operated the lock for a few days and then
trying to use it, you will need to pump the handle 4 to 6 times to
“recharge” the lock before using it.
During a multiple command sequence at the lock’s keypad when
you are trying to program many user PINs one after the other—say
more than 5 or 6 users, you will notice that the lock will start flash-
ing the Red light (LED) every second (typically after about 20 sec-
onds), indicating that the stored lock power is beginning to fade.
When you see this Red light flashing, you must pump the handle
again once to recharge which will enable you to continue program-
ming the lock.