27
DKX-10/DKX-19 High Security Lock Installation
The DKX-19 base plate installation is identical to the DKX-10 base plate installation. Refer to the included S~G 2740B lock
installation instructions. The S~G 2740B installation instructions are included with the lock.
Warning:
The electronics in the DKX-
10 are susceptible to damage from Electro-Static Discharge (ESD). Ensure proper
grounding.
A.
Place the 3.5" x 5 x
1
/
8
" backing plate against the b
ack of the DKX Series lock case assembly.
B. Feed the cables and outer tube through the 0.5
"
hole in the door while positioning the DKX-10, backing plate, and
cover bracket
(515034)
, oriented correctly as shown in above illustration, against the door.
C. Insert and slightly tighten two of the #10-32 machine screws
(115052)
(
top and bottom, diagonal
) to attach the
CDX-10, backing plate and cover bracket
(515034)
to the door.
Helpful Hint:
If available, another inner tube inserted from the dial ring side, with the cables carefully fed through it, can be
very helpful as a guide in feeding the cables through the door face.