Interface Hardware
Cable Assembly
These steps describe how to attach the rod end connector
(515040 or 515029)
, Figures 23 and 24, and stainless-steel mechanical
cable assembly
(116036)
to the lock and Rim Exit Device chassis. It also describes how to connect the cable assembly and
adjusting the cable length to achieve proper timing of the high security lock bolt retraction relative to the rim exit device latch bolt.
Install Knob Lever Assembly
A. Install the knob lever assembly once the lock assembly and the cover bracket
(515034)
are
successfully installed.
B.
Align the “
Double D
” hole in the knob lever
(515027)
with the “
Double D
” protrusion on the knob assembly
(116035)
,
and push the lever knob
(515027)
onto the knob assembly
(116035)
.
C. Align the screw hole in the manual knob
(515043)
with the hole in the knob lever
(515027)
, and hold into slotted
position.
D. Place the knob assembly screw
(515044)
through the hole in the manual knob
(515043)
and tighten into position.
Tighten to a minimum of 15 in.-lbs.
Cover Bracket
(515034)
Figure 22
Screw
(515044)
Knob Assembly
(116035)
Lever, Manual O/R
(515027)
Knob (515043)