background image

KTI-XD63709 

 

rev. 03/12/21

OWNER'S MANUAL

PORTABLE HYDRAULIC POWER KIT SETUP INSTRUCTIONS

This is the Safety Alert Symbol used for the SETUP INSTRUCTIONS section of this manual to alert you to potential 

personal injury hazards. Obey all instructions to avoid possible injury or death.

SETUP

1.   Refer to the parts list and drawing in this manual to identify parts mentioned in this setup procedure.
2.  

Before installing the force gage (P39) remove the plug A in the hose end of the pump (01). Thread the gage into the gage fitting 
(P41) and connect with the receiver (P42) by turning it clockwise. Make sure the connection is tight to prevent leakage.

3.   Open the release valve (P29) by turning it counterclockwise until it stops, then pump the handle 4 or 5 full incremented pump 

strokes to purge air from the hydraulic system.

4.  Install ram (02) or spreader (03) at the end of hose (P30) and secure the quick disconnect fittings together by hand tightening the 

threaded sleeve (R15) on the ram female coupler (R16) to the male coupler (P31) at the end of the hose (P30).

P39

P40

P41

P42

OPERATING INSTRUCTIONS

This is the Safety Alert Symbol used for the OPERATING INSTRUCTIONS section of this manual to alert you to potential 

personal injury hazards. Obey all instructions to avoid possible injury or death.

1.   Study the work to be done in order to determine the type ram and other attachments you will be using. 

Consult the enclosed 

chart titled “Applicable force for component set ups” in order to determine the maximum allowable force to be used in your 
specific setup.

 All rams have female hose disconnects attached to them, and the end of the hose has the male quick disconnect 

attached to it. Insert the end of the hose (P30) all the way in to the ram’s female quick disconnect 

(S11). Slide the female connector’s 

threaded sleeve 

(S10) on to the threads at the end of the hose (P30) and hand tighten. Never use any tools to tighten this connec-

tion.

2.   Consult this Owner’s Manual section titled APPLICABLE FORCE FOR COMPONENT SET UPS for typical attachment and extension 

tube setups and pay very close attention to the corresponding load ratings of certain attachment connections. The use of extension 
tubes, ram or plunger toes greatly reduces the hydraulic system’s capacity. When using extension tubes, put the shortest tubes on 
the ends of the setup.

3.   The pump (1) may be operated in the horizontal or vertical position but the pump (1) must point down when used in the vertical posi-

tion.

4.   Make sure all hydraulic and attachment connections are fully engaged and tight so ram force is straight in order to avoid off-center 

load conditions.

5.   During setup, make sure the hose routing avoids kinks, twists, curls or bends that will impede hydraulic fluid flow. Do not use the 

hose (P30) as a means to carry the kit components. Do not subject the hose (P30) to any hazards such as fire, extreme heat or cold, 
sharp surfaces, or heavy impact. IF A HOSE (P30) RUPTURES, BURSTS, OR NEEDS TO BE DISCONNECTED, IMMEDIATELY SHUT 
THE PUMP (1) OFF AND OPEN THE RELEASE VALVE (P29) TO RELEASE HYDRAULIC PRESSURE. NEVER GRASP A LEAKING 
PRESSURIZED HOSE, FITTING OR COMPONENT WITH YOUR HANDS OR SUFFER SERIOUS INJURY.

6.   Always use the pressure gauge (14) to make sure you are within the required force range when operating the system.
7.   In order to pump the ram

 

(2), it will be necessary to turn the release valve knob (P29) in a clockwise direction until tight. Tighten by 

hand only.

8.   Pumping the handle (P34) up and down transfers the hydraulic fluid from the pump’s reservoir (P6), through the hose 

(P30), in to the 

cylinder and extends the ram with each incremental pump stroke.

9.   To release the pressure and return the ram (2) back in to its cylinder (R14) , turn the release valve knob (P29) in a counterclockwise 

direction very slowly. Turning the release valve knob (P29) slowly will determine the speed in which the ram (2) will retract back into 
its cylinder (R14).

 

IMPORTANT:

 The pump includes an overload valve that will activate at the pump’s rated capacity only. If the setup requires a re-

duced rating, the operator is responsible for using the gauge to determine when to stop pumping since the overload valve is set to a 
higher rating.

10.  Make sure the ram (2) is completely retracted inside its cylinder (R14) before disconnecting the hose from the cylinder.
11.  The the hose (P30) and the ram (2) are repeatedly disconnected and exposed to shop or work place floors that are covered with dirt 

and debris. It is important to use the dust caps (P32) provided to prevent contaminants from entering the air and hydraulic systems.

12.  Based on continuous engagement and disengagement of the hose (P30) from the cylinder (R14), eventually it will become necessary 

to add hydraulic fluid to the pump’s reservoir (P6). Completely retract the ram before adding hydraulic fluid. Do not overfill in order 
to avoid personal injury and hydraulic malfunction. Use only hydraulic jack oil, 

Chevron Hydraulic Oil AW ISO 32 or its equivalent 

Unocal Unax AW 150

. Other fluids will cause damage to the hydraulic seals.

Содержание KTI-XD63709

Страница 1: ...10 TON PORTABLE RAM KIT OWNERS MANUAL SPECIFICATIONS KTI XD63709 Ram Capacity 10 Ton 7 250 psig Ram Minimum Height 12 68 Stroke 5 12 Fluid Capacity 22 oz Complies with ASME PASE 2019 Safety Standard w...

Страница 2: ...state and local safety standards User and bystanders must wear eye protection that meets ANSI Z87 1 and OSHA standards Do not use beyond rated capacity When attachments and adapters are used with the...

Страница 3: ...mp 1 must point down when used in the vertical posi tion 4 Make sure all hydraulic and attachment connections are fully engaged and tight so ram force is straight in order to avoid off center load con...

Страница 4: ...seal damage and kit failure never use alcohol hydraulic brake fluid or transmission oil in the pump 3 Every kit owner is responsible for keeping the kit labels clean and readable Use a mild soap solu...

Страница 5: ...Tool International Professional Lifting Equipment Authorized Warranty Center Be certain to include your name address and phone number along with proof of purchase information and a brief description o...

Страница 6: ...6370902 1 5 04 128mm Extension 1 5 3 RS6370902 1 8 50 216mm Extension 1 5 4 RS6370902 1 16 54 420mm Extension 1 06 07 08 09 10 11 05 1 05 2 05 3 05 4 12 13 04 01 02 03 P39 P40 P41 P42 14 Item Part Des...

Страница 7: ...P15 Copper Ring 1 P16 Piston Seat 1 P17 Anti dust Ring 1 P18 Sealing Ring incl 18 1 18 2 1 P19 Screw 1 P20 Piston 1 P21 Ball 1 Item Part Description Qty P22 Ball Cup 1 P23 Spring 1 P24 Screw 1 P25 O...

Страница 8: ...EAKDOWN KTI63709 KTI XD63709 Item Part Description Qty R01 RS10TR01 Cover 1 R02 Circlip 1 R03 Piston Rod 1 R04 Circlip 1 R05 Bushing 1 R06 Sealing Ring Set 1 R07 Pin 1 R08 Circlip 1 R09 Nut 1 R10 Spri...

Страница 9: ...ES MANUAL DEL PROPIETARIO ESPECIFICACIONES Ram Capacidad 10 Toneladas 7 250 psig Altura m nima del pist n 322mm 12 68 Recorrido 130mm 5 12 Capacidad Fluida 22 oz Cumple con las Normas de Seguridad ASM...

Страница 10: ...deben usar protecci n para los ojos que cumpla con ANSI Z87 1 y las normas de OSHA No use m s all de la capacidad nominal Cuando se usan accesorios y adaptadores con el kit la capacidad nominal del ki...

Страница 11: ...MBLAJE DE LOS COMPONEN TES para el ensamblaje de accesorios y tubos de extensi n t picos y preste mucha atenci n a las clasificaciones de carga cor respondientes de ciertas conexiones de accesorio El...

Страница 12: ...letamente antes de a adir l quido hidr ulico No lo sobrellene para as evitar lesiones personales y el mal funcionamiento hidr ulico Use s lo l quido hidr ulico para gato Chevron AW ISO 32 o Unocal Una...

Страница 13: ...agado junto con la comprobaci n de la fecha de compra a su Centro de Garant as Autorizado de Equipo de Levantamiento Profesional Autorizado de K Tool International m s cercano Aseg rese de incluir su...

Страница 14: ...KIT GUIDE DU PROPRI TAIRE SPECIFICATIONS Ram Capacit 10 Tonnes 7 250 psig Hauteur minimale du v rin 322mm 12 68 Course 130mm 5 12 Capacit en fluide 22 oz Conforme la Norme de S curit ASME PASE 2019 K...

Страница 15: ...utilisateur et les personnes pr sentes doivent porter une protection oculaire conforme aux normes ANSI Z87 1 et OSHA Ne pas utiliser au del de la capacit nominale Lorsque des accessoires et des adapta...

Страница 16: ...n de rallonges placer les tubes les plus courts aux extr mit s de l installation 3 La pompe 1 peut tre utilis e en position horizontale ou verticale mais elle doit pointer vers le bas lorsqu elle est...

Страница 17: ...st fr quemment branch et d branch il deviendra ventuellement n cessaire d ajouter du liquide hydraulique dans le r servoir de la pompe Abaisser compl tement le v rin avant d ajouter du liquide hydraul...

Страница 18: ...pement de levage K Tool International Assurez vous d inclure votre nom adresse et num ro de t l phone avec l information de preuve d achat et une br ve description du d faut pr tendu Le produit sera r...

Отзывы: