1 2
I I I .
VIEWING DATA
The K1600 INVENTORY SYSTEM will display tank inventory and information in either a
Multi-tank or Single-tank mode. In the single tank mode much of the pertinent information for
a tank can be viewed all at once. Due to obvious space constraints the Multi-tank mode will
display much less information for each tank. However, when required all data can easily be
viewed by the touch of a button.
Parameters which can be viewed and changed from either display mode are:
UNITS OF MEASURE
PRODUCT NAMES AND SPECIFIC GRAVITIES
ALARM LEVEL SETPOINTS
TRANSMITTER ZERO OFFSET VALUES
TIME AND DATE
TO VIEW
PRESS
MULTI-TANK SCREEN DISPLAYS SINGLE-TANK SCREEN
DISPLAYS
UNITS
N / A
Ô
PRODUCT
IN TANKS
PROD
1 WHEY 5 SKIM
2 MILK 6 OIL
3 WATER 7 SUCRSE
4 CREAM 8 JUICE
CHANNEL NUMBER
PRODUCT NAME
TANK 1 42730 GAL.
CH: 1 **HI** LEVEL
CREAM 0.998 SPGR
97% FULL
PRODUCT NAME AND SPECIFIC
GRAVITY ALWAYS DISPLAYED
1 WHEY G 5 SKIM
2 MILK 6 OIL
3 WATER 7 SUCRSE
4 CREAM 8 JUICE
TANK 1 42730 GAL.
CH: 1 **HI** LEVEL
CREAM 0.998 SPGR
97% FULL
UNITS OF MEASURE ARE
ALWAYS DISPLAYED
UNITS OF MEASURE ARE
ALWAYS DISPLAYED