![K-Rain PRO EX 2.0 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/k-rain/pro-ex-2-0/pro-ex-2-0_instruction-manual_648539013.webp)
Installation, Programming and Operation Manual
13
www.krain.com |
SENSOR
OPEN CIRCUIT DETECTION
CLEAR
The SENSOR on/off feature allows the user
to enable or disable the SENSOR terminals for
each individual station.
The on/off feature is used in irrigation systems
where it is desirable for a Rain Sensor to operate
or not operate for a specific station(s).
1. Turn the dial to SPECIAL FEATURES. Display
will show “SEASONAL ADJUST % 100.”
2. Press NEXT button until “SENSOR” is
displayed.
3. Press BACK and NEXT button simultaneously
to enter the sensor ON / OFF feature. The
display will show “ACTIVE” and all stations.
4. Press the BACK or NEXT buttons to select
desired station.
5. Press the UP or DOWN buttons to activate
(ON) or bypass (OFF) the station.
6. Return the dial to AUTO.
The open circuit detection feature prevents pump
and station operation when the controller detects
an open circuit.
The open circuit detection feature can only
be enabled (ON) or disabled (OFF) globally for
all stations.
1. Turn the dial to SPECIAL FEATURES. Display
will show “SEASONAL ADJUST % 100.”
2. Press the NEXT button until “OPENOFF” is
displayed.
3. Press the “UP” or “DOWN” buttons to
activate or deactivate the open circuit
detection feature.
4. Return the dial to AUTO.
NOTE:
If the controller is connected to the
INTERNET, and the program settings have
been saved, you can clear the controller and
then restore the previous program settings in
order to automatically connect the controller
back to the INTERNET and continue to program
your controller from your smartphone or tablet.
If the controller is reset to factory default
AND the program WAS NOT SAVED as well
as connected to the INTERNET via WiFi Hub,
the connection must be re-established by
reconnecting the controller to the hub and
reprogramming. See quick start guide.
The CLEAR feature allows the user to erase
all current programing and restore the original
factory default program (all available stations,
everyday for ten minutes).
1. Turn the dial to SPECIAL FEATURES.
The display will show “SEASONAL
ADJUST % 100.”
2. Press the NEXT button until “CLEAR”
is displayed.
3. To enter the CLEAR feature press the
UP or DOWN button and the display
should now show “CLEAR*.”
4. Press the NEXT button to clear the
current program. The display will briefly
show “CLEARED” before automatically
advancing to the next available feature.
5. Return the dial to AUTO.
sensor
openoff
clear