32
Return Code
ERR_NoError
ERR_BoardNoInit
ERR_Query_Status
A.2.7 TRIG_Trigger_Route_Query
Description
Acquires the current trigger signal routing path
Supported Controllers
PXI-63980, PXI-63930,
Syntax
C/C++
◦ I16 TRIG_Trigger_Route_Query (U32* source,
◦ U32* dest, U32* halfway)
Visual Basic
◦ TRIG_Trigger_Route_Query (source As Long, dest
◦ As Long, halfway As Long) As Integer
Parameters source
source
Returns to the current source of trigger routing, with possible values including:
Available Definition
Defined Value
PXI_TRIG_VAL_NONE
0
PXI_TRIG_VAL_SMB
2
PXI_TRIG_VAL_SOFT
3
PXI_TRIG_VAL_TRIG0
111
PXI_TRIG_VAL_TRIG1
112
PXI_TRIG_VAL_TRIG2
113
PXI_TRIG_VAL_TRIG3
114
PXI_TRIG_VAL_TRIG4
115
PXI_TRIG_VAL_TRIG5
116
PXI_TRIG_VAL_TRIG6
117
PXI_TRIG_VAL_TRIG7
118
dest
Returns to the current destination of trigger routing, with possible values including:
Available Definition
Defined Value
PXI_TRIG_VAL_NONE
0
PXI_TRIG_VAL_SMB
2
PXI_TRIG_VAL_TRIG0
111
PXI_TRIG_VAL_TRIG1
112
PXI_TRIG_VAL_TRIG2
113