No.51922
TM-H1700G
30
Item
Test equipment
Test points
Adjustment
locations
Adjustment procedure
NTSC 3.58
PHASE
adjustment
Signal generator
(Full colour bar)
Oscillo-scope
TP-47B
TP-E(
)
[CRT SOCKET
PWB]
S05 (NTSC PHASE)
[SERVICE MENU]
1. Input a NTSC 3.58 full colour bar signal.
2. Connect the oscillo-scope probe to TP-47B and
TP-E(
).
3. Select the SIGNAL BLOCK from SERVICE
MENU.
4. Select the S05 item.
5. Adjust the S05 to become the voltage different
between 75% white and magenta to 0V
±
2Vp-p
as shown in figure.
BL
B
R
Mg
G
Cy
Y
W
75%
0V
±±±±
2V