No. 51922
TM-H1700G
34
Item
Test equipment
Test points
Adjustment
locations
Adjustment procedure
Under scan
Horizontal
Size
Horizontal
center
Adjustment
Signal generator
(Circle pattern)
DD01 (H. CENTER)
DD02 (H. SIZE)
[SERVICE MENU]
22. Input the PAL circle pattern signal.
23. Select the under scan mode.
24. Select the DD01 and adjust it to the left and right
blanking width become equal.
25. Select the DD02 and adjust it to the left and right
blanking width become the value given below.
Under scan
Horizontal
Size
Horizontal
center
Adjustment
Signal generator
(Crosshatch pattern)
DD07
(E-W PARABOLA)
DD08
(E-W CORNER)
[SERVICE MENU]
26. Confirm the side pincushion of the four corners in
the screen.
27. If not optimum, adjust the DD07 and DD08 to
become correctly.
28. If the warps are happened by adjust the side
pincushion, readjust the above-mentioned DD01
and DD02.
16:9
Under scan
Side
pincushion
Adjustment
Signal generator
(Crosshatch pattern)
DF07
(E-W PARABOLA)
DF08
(E-W CORNER)
[SERVICE MENU]
29. Switch the aspect ratio to the 16:9 mode.
30. Confirm the side pincushion of the four corners in
the screen.
31. If not optimum, adjust the DF07 and DF08 to
become correctly.
32. If the warps are happened by adjust the side
pincushion, readjust the above-mentioned DD01
and DD02.
33. Turn the scan size to the normal.
Horizontal
Blanking Width
(one side of screen)
6
~
~
~
~
9mm
6
~
9mm
6
~
9mm
PICTURE
SIZE
Effective
screen size
Only for PAL
signal
adjustment