2.10 Maintenance Mode
2.10.1 Outline
This unit is also equipped with an RS-232C port as an interface
for external equipment other than the SCSI interface which is
used for connection to the host computer. The RS-232C port is
used mainly for the following two purposes:
(a) Remote Maintenance:
It can be used for remote diagnostic operation by connecting
to the public telephone line via a modem.
(b) Direct Maintenance:
It can be used for diagnostic operation by direct connection
to a computer, etc.
In either way, while this unit is operated in the system the me-
chanical operation checking, which is one of the checking func-
tions of the self-diagnosis operation, is not available.
*Judgment whether remote or direct maintenance Checks
whether the modem is connected or not when the power is
turned ON, and judges the unit is in the “remote maintenance”
or “direct maintenance” mode.
· The modem control AT command (Z: Reset) is transmitted to
the RS-232C port. And if there is a response, the unit is oper-
ated as the “remote maintenance” mode, and if there is no
response, the unit is operated as the “direct maintenance”
mode.
2.10.3 Maintenance Types and Conditions
1
Operating environment status
Outputs the environmental conditions including the type of
this unit (Model No.), status of connected drives, SCSI ID
No. setting and ROM version, etc.
2
Trouble contents check
Outputs the trouble information stored in this unit.
3
Self diagnostic function
Performs the preset specific operations and outputs the re-
sults as the status. Operations
1
and
2
are available at any
time. The operation
3
is available only when this unit is in
the maintenance mode. Regardless of the currently selected
maintenance mode (remote or direct), all the peripheral com-
ponents must be turned on before turning on the power to
this unit.
2.10.4 Activating the Maintenance Mode
To activate the maintenance mode with this unit...
1
Set the maintenance disc in the address 1 before turning the
power ON.
2
While pressing the MODE switch on the front panel, turn the
power switch to ON.
2.10.5 Maintenance Program
To perform maintenance on this unit, the maintenance program
software must be installed on the PC connected.
• Connector: D-Sub 9-pin (male)
• Pin Layout
2.10.2 Electrical Specifications
• Signal Format
Modem
H O S T
Modem
P C
Library
Library
H O S T
Library
H O S T
P C
(a) Remote maintenance
(b) Direct maintenance
RS-232C
RS-232C
S C S I
S C S I
RS-232C
S C S I
●
Maintenance by
the same host
●
Maintenance using
exclusive PC
Public Tel line
1
DCD (IN)
6
DSR
2
RXD (IN)
7
RTS (OUT)
3
TXD (OUT)
8
CTS (IN)
4
DTR (OUT)
9
NC
5
S-GND
Signal Level
RS232C
Communication System
Asynchronous half-duplex
Transfer Rate
9600 bps
Character
Start bit: 1
Data: 8 bits
Parity: None
Stop bit: 1
Codes used
ASCII character code
Modem Control Command
Compliant to Hayes AT command
Compatible Modem
ITU-T V.32
1
2
3
4
6
7
8
9
5
NOTES:
In the “direct maintenance” mode, the host computer must
not respond to an AT command.
2-18
Содержание MC-8200LU
Страница 57: ...3 1 SECTION 3 DIAGRAM AND CIRCUIT BOARDS 3 1 CHASSIS BLOCK DIAGRAM ...
Страница 58: ...3 2 3 2 SCSI BLOCK DIAGRAM ...
Страница 61: ...3 5 3 5 3 5 CHASSIS CIRCUIT BOARD ...
Страница 62: ...3 6 3 6 3 6 SCSI SCHEMATIC DIAGRAM 0 0 IC4 MBM29F200PC90PF R28 390 ...
Страница 63: ...3 7 3 7 3 7 SCSI CIRCUIT BOARD ...
Страница 66: ...MAIL SLOT MOTOR MECHANISM SW 3 10 3 10 3 10 MAIL SLOT SCHEMATIC DIAGRAM ...
Страница 67: ...3 11 3 11 MAIL SLOT CIRCUIT BOARD MAIL SLOT BOARD POSI IN BOARD SENSOR BOARD ...
Страница 68: ...C4 0 001 3 12 3 12 DISPLAY SCHEMATIC DIAGRAM QLD0205 001 ...
Страница 70: ...3 14 3 14 3 14 LVD SCHEMATIC DIAGRAM ...
Страница 71: ...3 15 3 15 3 15 LVD CIRCUIT BOARD ...