MEMO
0
Indicator display during normal condition.
Indicator
Description
STANDBY/ON
LAMP
WARNING
Light On (Red)
-
-
When in the standby mode.
Light On (Green)
-
-
When power is supplied (operating mode).
Blinking (Red)
-
-
When cooling down (cool down mode). (P. 31)
Blinking (Green)
-
-
When the projected image is temporarily hidden. (P. 32)
Warning Status
The latest error code (Warning Status) appears in the “Main” menu when an abnormality occurs in the projector.
Error details are as follows:
Error Code
Meaning
2
The lifetime of the LD block has exceeded 20,000 hours.
8
Abnormally high temperature in the projector.
9
Abnormally high temperature around the intake vent.
A
Abnormally high ambient temperature around the lamp.
15
The safety switch is activated.
30
Trouble with CPU circuit board.
31
Trouble with MAIN circuit board.
32
Trouble with DD-RB circuit board.
33
Trouble with DD-G circuit board.
34
Trouble with SUB CPU circuit board.
41
Cooling fan for the illumination system (PCS) has stopped.
42
Cooling fan for the circuit power has stopped.
43
Cooling fan for the DD circuit board has stopped.
44
Cooling fan for the MAIN circuit board has stopped.
46
Cooling fan for the PFC power has stopped.
48
Cooling fan for the DD RB has stopped.
4A
Exhaust fan for the LD Driver has stopped.
4B
Cooling fan for the LD Bank1 has stopped.
4C
Cooling fan for the LD Bank2 has stopped.
50
Trouble with mechanical shutter.
54
Others