Parameters used for the data format
The following 2 types of parameters are used for command and response data:
(1) ON/OFF (2) Special Parameter
Each parameter is as follows:
(1) ON/OFF
Shows the status (ON or OFF) of the unit, such as POWER and HIDE.
Character
Hex
Meaning
0
30
OFF
1
31
ON
(2) Special parameters
Operation mode parameters
Character
Hex
Meaning
0
30
Standby state
1
31
Power ON state
2
32
Cooling state
3
33
Emergency cooling state
4
34
Emergency state
DHCP client parameters
Character
Hex
Meaning
0
30
DHCP
1
31
STATIC IP
IP address parameters
Display the IP address using the dot (“.” (2HE)) delimiter.
Example: “192.168.0.10”
External control command table
Function
Command
Setting
Asking
Data Type
Power On
ELSE
Power On
ELSE
ON/OFF
Special Parameter
Power
U0F
X
(OFF)
X
(ON)
-
-
X
-
Hide
U00
X
-
X
-
X
-
Operation Mode
UA0
-
-
X
X
-
Standby...
DHCP Client
UD2
X
X
X
X
-
DHCP...
IP Address
UD3
X
X
X
X
-
192.168. ...
Network Restart
UDC
X
X
X
X
-
“0” Fixed
MEMO
0
After configuring “DHCP Client” and “IP Address”, execute “Network Restart”.