Known Problems and Limitations
43
Release 11.1.0
Known Problems and Limitations
This section identifies the known problems and limitations in this release. For more
information about known problems that were discovered at customer sites, you
can log in to the JUNOSe Knowledge Base at https://www2.juniper.net/kb/, enter
the defect ID number in the Search by Keyword field, and click Search.
ANCP
On an E320 router that has established 3000 ANCP adjacencies with a client
and traffic is initiated, the following behavior occurs sporadically: All existing
Telnet sessions are disconnected and no new Telnet sessions can be
established for several minutes. [Defect ID 83872]
ATM
The line module resets when you issue the
show nbma arp
command after
you have configured NBMA interfaces on an ATM line module. [Defect ID
88491]
When 16,000 PPPoA interfaces are configured on an OCx/STMx ATM line
module paired with an OC3-4 I/O module in an ERX14xx model, ERX7xx
model, or ERX310 router, Ping traffic passing through the line module on the
restarting router experiences an outage of 103 seconds, which is beyond the
maximum limit, after a unified ISSU from JUNOSe Release 9.2.0p1-0 to
9.3.0b0-12. This outage does not occur when the same configuration is applied
on a Gigabit Ethernet interface. [Defect ID 179794]
When you reload an ATM line module that is configured with NBMA circuits as
passive OSPF interfaces and that has established OSPF adjacencies and IBGP
peers (configured on Gigabit Ethernet interfaces), the transmission of OSPF
hello packets might be affected until all the NBMA interfaces have initialized.
[Defect ID 46157]
Work-around:
Either remove the passive OSPF interface statements on the
NBMA interfaces, or statically configure the OSPF cost on the NBMA interfaces.
When a mirror rule that triggers on username is employed for packet mirroring
of dynamic IP subscribers over ATM, removal of the rule does not disable
packet mirroring. [Defect ID 175356]
Work-around:
Use a mirror rule that triggers on account session ID rather than
on username.
The ATM peak cell rate (PCR) does not appear in the L2TP Calling Number AVP
for the first PPP session when the ATM shaping parameters were configured by
RADIUS return attributes. [Defect ID 60933]
When you issue the
no atm atm1483 auto-configure
upperInterfaceType
lockout-time
command in Profile Configuration mode, the lockout time range
does not revert to the default values. [Defect ID 66544]
When one or more ATM1483 attributes appears in a profile, the
show
configuration include-defaults
command fails to display the default values for