4.9.2
Display Messages
Display
Meaning
Corrective measures
Err01
Load cell signal is not stable
Automatic
Err02
Capacity of the weighing system
exceeded
Automatic after load has been
removed
Err03
Gross weight is negative.
This is not permitted.
Automatic
Err04
Outside the zero range
Press any key
Err06
Input signal too high
Automatic after adjustment of input
signal
Err08
Adjustment outside of range
(negative)
Automatic
Err09
Adjustment outside of range (signal
too low)
Automatic
Err10
Adjustment value 2 (3) is lower
than value 1 (2)
Automatic
Err14
Switching value 2 < switching value
1
This is not permitted.
Automatic
CAL-J
Calibrated version only
No action permitted
If no action is required, remove
jumper JP1.
Z
Following this action, a
complete reconfiguration
and recalibration of the
system is required.
Err98
Adjustment point must be higher
than the previous one
Automatic
Err99
Operation only permitted on power-
up unit
Automatic
----
Load cell signal is negative
Raise load handler
Err_L
Truck is not level
(calibrated version only)
Level the truck
Weighing system battery is empty
Charge the battery
OimL
Action not permitted
(calibrated version only)
Automatic
ntEP
Action not permitted
(calibrated version only)
Automatic
SCALL
Test path number outside of range
Contact service
ESoFt
Incorrect firmware combination
Contact service
EConF
P96 not set
Set P96 according to the used
hardware
78
11.19 en-GB