Test operation is switched on for 5 minutes, afterwards the motion detector switches to
automatic operation again.
Function
Value
Sensitivity
100 %
Detection area
180 °
Brightness threshold
Day mode
run-on time
1 second
i
By pressing the
À
button, you can switch to automatic operation at any time.
Performing a reset
During a reset, the motion detector is reset to the factory settings.
o
Press the
Ú
button for longer than 10 seconds.
Function
Value
Sensitivity
100 %
Detection angle
180 °
Brightness threshold
10 lux
run-on time
30 seconds
Operating location
Indoors
Night light function
Switched-off
Presence simulation
Switched-off
i
If the
Ú
button is pressed for less than 10 seconds, only a few functions are
terminated (see chapter 4. Operation on a main unit).
5 Operation on a 3-wire extension insert
Only a few settings are possible in combination with a 3-wire extension insert.
-
Setting sensitivity (see Chapter Operation on a main unit)
-
Use outdoors (see Chapter Operation on a main unit)
-
Extension Off for 2 hours or Continuous off
3-wire extension insert Off for 2 hours
o
Press
Ã
button of the IR remote control.
Extension is switched off for 2 hours. The extension is in automatic operation again after
the time has elapsed.
i
By pressing the
À
button of the IR remote control, you can switch to automatic
operation at any time.
3-wire extension insert Continuous off
o
Press
Á
button of the IR remote control, alternatively press button (5) on the
motion sensor.
Extension is switched off continuously. The red LED lights up.
i
By pressing the
À
button of the IR remote control, alternative button (5) on the motion
detector, you can switch to automatic operation at any time.
8/13
32576803
J:0082576803
03.05.2011
Light Management