background image

Carry out optional adjustment for use outdoors. 

Switching on optional night light function 

Configure dimming phase optionally in combination with dimming inserts. 

Configure short time operation optionally in combination with switching inserts. 

Set brightness threshold. 

Set follow-up time. 

7 Appendix 

Remove empty batteries immediately and dispose of in an environmentally friendly 
manner. Do not throw batteries into household waste. Consult your local authorities 
about environmentally friendly disposal. According to statutory provisions, the end 
consumer is obligated to return used batteries. 

7.1 Technical data 

Ambient temperature 

-15 ... +45 °C 

Protection rating 

IP 20 

Brightness setting 

approx. 1 ... 200 lx (and day operation) 

run-on time 

approx. 10 s ... 60 min 

Sensitivity 

25 ... 100 % 

Lockout time 

approx. 0.3 ... 4 s 

Installation height 

1.10 / 2.20 m 

Detection angle 

180 ° 

cross walking range 

approx. 12 x 6 m 

walk to walking range 

approx. 8×4 m 

Short time operation 
pulse duration 

approx. 0.3 s 

pulse stop 

approx. 2.7 s 

IR remote control 
Battery type 

1×lithium CR 2025 

7.2 Troubleshooting 

Motion detector does not switch on 

Cause 1: The ambient brightness is greater than the set brightness value. 

Set brightness value. 

Cause 2: Motion detector does not detect any motions. 

Increase sensitivity. 
Switch on all sensors. 
Switch on motion detector on 3-wire extension insert. 

Cause 3: Off for 2 hours or Continuous off is activated 

Switch on automatic mode. 

Motion detector switches on without motions. 

Cause 1: Presence simulation is activated. Motion detector switches to saved times. 

Switch on automatic mode. 

Cause 2: Interference sources in the detection area. 

Remove interference sources if possible. 
Reduce sensitivity. 
Limit detection area. 

11/13 

32576803 
J:0082576803 

03.05.2011 

Light Management  

Universal automatic switch 180° 2.20 m 

Содержание AS 1280-1 Series

Страница 1: ...Device is not suitable for disconnection from supply voltage The load is not electrically isolated from the mains even when the device is switched off Do not press on the sensor window Device can be...

Страница 2: ...imit is reached To avoid any light swings caused by a cooling illuminant the motion detector does not evaluate any motion signals for a brief lockout time after switching off The motion detector adjus...

Страница 3: ...he light is switched on for the run on time after mains return Longer than 2 seconds The motion detector goes through a self test for approx 40 seconds after mains return The light is first switched o...

Страница 4: ...er than 10 seconds Adjusting detection angle Brightness threshold approx 1 lux night operation Brightness threshold approx 10 lux switching takes place during twilight Brightness threshold 150 lux set...

Страница 5: ...switched on output HLK continues switching motion dependent Switching off On for 2 hours or Continuous on o Press button for Continuous on function press alternative button 7 on the motion detector A...

Страница 6: ...tton or 2 wire extension insert over entire surface for longer than 3 seconds Switch on brightness is saved For confirmation the light is switched off briefly and switched on again i In the state as s...

Страница 7: ...an 10 seconds i No run on time is set in short time operation i With the HVAC insert the function is only executed for Kanal 1 output i To switch off short time operation press Reset button for less t...

Страница 8: ...e extension insert Only a few settings are possible in combination with a 3 wire extension insert Setting sensitivity see Chapter Operation on a main unit Use outdoors see Chapter Operation on a main...

Страница 9: ...o Avoid interference sources in the detection area Interference sources such as heaters fans air conditioners and cooling illuminants can lead to unwanted switching Motions crosswise to the motion det...

Страница 10: ...with the frame onto the concealed insert i Do not connect any main units in parallel This can lead to light swings 6 2 Commissioning Insert battery into IR remote control i Keep contacts of batteries...

Страница 11: ...s Installation height 1 10 2 20 m Detection angle 180 cross walking range approx 12 x 6 m walk to walking range approx 8 4 m Short time operation pulse duration approx 0 3 s pulse stop approx 2 7 s I...

Страница 12: ...ity Limit detection area Cause 2 On for 2 hours or Continuous on is activated Switch on automatic mode Cause 3 Night light function is switched on The light stays on at 20 brightness Switch off night...