7.1 Technical data
Ambient temperature
-15 ... +45 °C
Protection rating
IP 20
Brightness setting
approx. 1 ... 200 lx (and day operation)
run-on time
approx. 10 s ... 60 min
Sensitivity
25 ... 100 %
Lockout time
approx. 0.3 ... 4 s
Installation height
1.10 / 2.20 m
Detection angle
180 °
cross walking range
approx. 12 x 6 m
walk to walking range
approx. 8×4 m
Short time operation
pulse duration
approx. 0.3 s
pulse stop
approx. 2.7 s
IR remote control
Battery type
1×lithium CR 2025
7.2 Troubleshooting
Motion detector does not switch on
Cause 1: The ambient brightness is greater than the set brightness value.
Set brightness value.
Cause 2: Motion detector does not detect any motions.
Increase sensitivity.
Switch on all sensors.
Switch on motion detector on 3-wire extension insert.
Cause 3: Off for 2 hours or Continuous off is activated
Switch on automatic mode.
Motion detector switches on without motions.
Cause 1: Presence simulation is activated. Motion detector switches to saved times.
Switch on automatic mode.
Cause 2: Interference sources in the detection area.
Remove interference sources if possible.
Reduce sensitivity.
Limit detection area.
11/13