9
Pressure vessel
Pressure tested at: 4-25 litre:
40-50 litre:
Directions for use
Application
Receiver for compressed air.
Receiver specifications See name plate.
Installation
Tubes, etc. must be installed with
suitable materials.
Placement
Observe the working temperature
of the receiver.
Ensure sufficient room for
inspection and maintenance.
The receiver must be kept in a
horizontal position.
Corrosion protection
The surface treatment must be
maintained as required.
Internal inspection at least every
5 years.
Drain condensate at least once a week.
Alternation/repair
No welding must be made on
pressurised parts.
Safety valve
Ensures that PS will not be exceeded.
Never adjust to a higher pressure
than PS.
The capacity of the valve must be
calculated in accordance with the
volume of air supplied by the
compressor.
(PS = Maximum working pressure
of the receiver)
Declaration of Conformity
NOTE: The declaration of conformity is only valid for units
operating at 20 V/50 Hz, x400 V/50 Hz, 12 V DC or 24 V DC.
The manufacturer, JUN-AIR International A/S, declares that the
products mentioned in this manual are in conformity with:
• 87/404/EEC - 90/488/EEC - 9/68/EEC Council Directive
relating to Simple Pressure Vessels
• 98/7/EC Machinery Directive
• 89/6/EEC EMC Directive
• 7/2/EEC Low Voltage Directive
Flemming Petersen
Quality Manager
24 bar
18.3 bar
Operating manual
GB
Содержание 2xOF302-40B
Страница 2: ......
Страница 4: ......
Страница 36: ......
Страница 43: ...27 0070011 Dimensions OF301 12 24V DC 0070015 Dimensions OF301 12 24V DC horizontally mounted Technical data...
Страница 44: ...28 0070010 Dimensions OF301 60Hz 0070013 Dimensions OF301 50Hz Technical data...
Страница 46: ...30 0080010 Dimensions OF302 0080011 Dimensions OF302 horizontally mounted Technical data...
Страница 49: ...33 6072890 Electrical drawing model OF301 302 B D 100 240V 50 60Hz Diagrams...
Страница 50: ...34 6072880 Electrical drawing model OF301V 302V 100 240V 50 60Hz Diagrams...
Страница 51: ...35 6073060 Electrical drawing model 2xOF301 2x302 B 100 240V 50 60Hz Diagrams...
Страница 52: ...36 6073061 Electrical drawing model 2xOF301 2x302 B D 100 240V 50 60Hz Diagrams...