EN
41
IMPORTANT:
Function check of automatic reversing.
It is very important that automatic reversing
functions, and it must therefore be checked
at regular intervals. The door should
automatically go back to open position if it
comes into contact with an object 100 mm
high placed on the floor. Incorrect adjustment
can result in a risk of serious personal injury
when closing. Check every month, and adjust
if necessary.
Place an object 100 mm high on the floor
under the door leaf. Close the door with the
door opener. The door should automatically
go back to open position when it comes into
contact with the object. If the door stops at the
test obstacle, without going back, remove the
obstacle and reset the limit position. Repeat
the function check.
If the door reverses at the test obstacle, remove
the obstacle and run a complete opening/
closing cycle. The door must not reverse when
the door leaf reaches its closed position. If this
happens, reset the limit position setting and
the settings for opening and closing force. Do
a function checkof the automatic reversing
again.
FIG. 26
Lighting
The light switches on automatically when the
product is activated. The light switches off
automatically if no buttons are pressed on the
control box or remote controls for 3 minutes.
CONNECTING ACCESSORIES
On the side of the drive unit there is a port for
connection of accessories (figure 3).
1. Terminal 1: Door control button
2. Terminal 2: Door control button
3. Terminal 3: Photocell (security function)
4. Terminal 4: Photocell (security function)
5. Terminal 5: Auxiliary outlet 24 VDC (+)
6. Terminal 6: Auxiliary outlet 24 VDC (–)
FIG. 27
NOTE:
The output current from terminal 5 and 6 is
less than 100 mA.
MAINTENANCE
The product requires very little maintenance
if it is installed correctly. The chain should be
lubricated every 6 months.
EVERY MONTH
• Function check of automatic reversing and
adjust, if necessary.
• Open and close the door manually and
check that it runs smoothly and easily.
Contact a qualified service technician if
the door is sluggish, fastens or is
unbalanced.
• Check that the door opens and closes
completely. Adjust the limit positions and/
or opening and closing force, if necessary.
EVERY 6 MONTHS
• Release the carrier and check the chain
tension. Adjust, if necessary.
EVERY YEAR
• Lubricate the door mechanism rollers,
bearings and hinges. The door opener
requires no further lubrication. Apply
grease sparingly on the door guides.
Limit position and force settings
The limit positions and opening and closing
force should be checked and set when the
product is installed. Variable weather and
environmental conditions can result in minor
variations in the movement of the door, which
can make it necessary to adjust these settings
especially during the first year.
Содержание Hard Head 018980
Страница 5: ...1 2 1 2 11 14 3 4 5 6 8 9 12 13 10 17 15 16 7 ...
Страница 6: ...3 5 4 1 2 4 5 1 2 4 5 3 1 2 4 5 3 6 1 2 4 5 3 3 ...
Страница 7: ...7 8 9 2 3 1 1 6 4 2 3 5 7 ...
Страница 8: ...11 12 1O 2 3 1 9 8 6 7 5 3 2 1 5 1 2 A A 3 4 4 ...
Страница 9: ...13 14 5 3 2 4 4 3 2 5 6 1 1 2 3 ...
Страница 10: ...16 5 1 1 2 5 3 6 4 2 3 5 5 3 3 5 3 15 50 mm 2 150 mm 6 1 1 2 2 ...
Страница 11: ...18 17 2 2 1 3 5 2 3 3 5 5 4 4 1 1 19 ...
Страница 12: ...20 4 5 7 3 6 7 7 6 6 6 3 3 1 2 2 9 5 4 4 5 8 21 ...
Страница 13: ...22 ...
Страница 14: ...23 ...
Страница 15: ...24 ...
Страница 16: ...25 ...
Страница 17: ...27 26 1 2 3 4 5 6 1 ...
Страница 55: ...PL 31 ...