EN
40
Adjusting the opening force
1. Press the SET button for at least 4
seconds. The display shows 1 (skip this
step if the setting of the opening force is
made immediately after setting the limit
position).
2. Press the UP button until 3 is shown in
the display (figure 1). Tap the SET button.
3 starts flashing in the display (figure 2).
The opening force can now be set.
3. Tap the UP button. A number from 1
to 9 flashes in the display (figure 3) to
show the set opening force. The standard
setting is 4. The minimum adjustable
force is indicated as 1 and the maximum
as 9. The number/force increases by 1
each time the UP button is pressed. The
number/force is reduced by 1 each time
the DOWN (figure 4) button is pressed.
4. Press the SET button to save the setting
when the required opening force has been
set. 3 is shown in the display (figure 5).
Other parameters can now be set. Press
the SET button for a few seconds, until H
is shown on the display (figure 6). The
opening force is now set.
FIG. 23
Adjusting the closing force
1. Press the SET button for at least 4
seconds. The display shows 1 (skip this
step if the setting of the closing force
is made immediately after setting the
opening force).
2. Press the UP button until 4 is shown in
the display (figure 1). Tap the SET button.
4 starts flashing in the display (figure 2).
The closing force can now be set.
3. Tap the UP button. A number from 1 to 9
flashes in the display (figure 3) to show
the set closing force. The standard setting
is 4. The minimum adjustable force is
indicated as 1 and the maximum as 9. The
number/force increases by 1 each time the
UP button is pressed. The number/force is
reduced by 1 each time the DOWN (figure
4) button is pressed.
4. Press the SET button to save the setting
when the required closing force has been
set. 4 is shown in the display (figure 5).
Other parameters can now be set. Press
the SET button for a few seconds, until H
is shown on the display (figure 6). The
closing force is now set.
FIG. 24
Setting automatic closing
1. Press the SET button for at least 4
seconds. The display shows 1 (skip this
step if the setting of the closing force
is made immediately after setting the
closing force).
2. Press the UP button so that 5 is shown in
the display (figure 1). Tap the SET button.
5 starts flashing in the display (figure 2).
The function for automatic closing can
now be activated/deactivated and its
delay set.
3. Tap the UP button. A number from 0 to
9 flashes in the display (figure 3) to show
the set closing delay. The standard setting
is deactivated automatic closing, which is
indicated by 0 (figure 3). The minimum
delay is 1 minute, and the maximum delay
is 9 minutes. The number/delay increases
by 1 (1 minute) each time the UP button is
pressed. The number/delay is reduced by
1 (1 minute) each time the DOWN (figure
4) button is pressed. 0 indicates that
automatic closing is deactivated.
4. Press the SET button to save the setting
when the required delay has been set. 5
is shown in the display (figure 5). Other
parameters can now be set. Press the SET
button for a few seconds, until H is shown
on the display (figure 6). Automatic
closing is now set.
FIG. 25
Содержание Hard Head 018980
Страница 5: ...1 2 1 2 11 14 3 4 5 6 8 9 12 13 10 17 15 16 7 ...
Страница 6: ...3 5 4 1 2 4 5 1 2 4 5 3 1 2 4 5 3 6 1 2 4 5 3 3 ...
Страница 7: ...7 8 9 2 3 1 1 6 4 2 3 5 7 ...
Страница 8: ...11 12 1O 2 3 1 9 8 6 7 5 3 2 1 5 1 2 A A 3 4 4 ...
Страница 9: ...13 14 5 3 2 4 4 3 2 5 6 1 1 2 3 ...
Страница 10: ...16 5 1 1 2 5 3 6 4 2 3 5 5 3 3 5 3 15 50 mm 2 150 mm 6 1 1 2 2 ...
Страница 11: ...18 17 2 2 1 3 5 2 3 3 5 5 4 4 1 1 19 ...
Страница 12: ...20 4 5 7 3 6 7 7 6 6 6 3 3 1 2 2 9 5 4 4 5 8 21 ...
Страница 13: ...22 ...
Страница 14: ...23 ...
Страница 15: ...24 ...
Страница 16: ...25 ...
Страница 17: ...27 26 1 2 3 4 5 6 1 ...
Страница 55: ...PL 31 ...