– 92 –
Y origin retrieval error
Y origin sensor does not change.
Turn OFF the power switch and check whether
CN63 of INT circuit board or CN43 of MAIN
circuit board is discoonected or loose.
Work clamp foot origin
Work clamp foot origin sensor does not
Turn OFF the power switch and check whether
retrieval error
change.
CN64 of INT circuit board or CN44 of MAIN
circuit board is discoonected or loose.
Needle thread clamp origin Needle thread clamp origin sensor does
Turn OFF the power switch and check whether
retrieval error
not change.
CN65 of INT circuit board or CN45 of MAIN
circuit board is discoonected or loose.
Feed trouble error
Timing lag between feed and main shaft
Turn OFF the power switch and check whether
has occurred.
coupling of the main motor is loose.
Communication error between
Comminication between the panel and
Turn OFF the power switch and check whether
panel and MAIN
MAIN cannot be performed.
CN34 of MAIN circuit board is loose.
Communication error between
Comminication between MAIN and SDC
Turn OFF the power switch and check whether
panel and SDC
cannot be performed.
CN32 of MAIN circuit board or CN15 of SDC
circuit board is disconnected or loose.
MAIN memory write-in
Memory write-in of MAIN circuit board
Turn OFF the power switch and check the ins-
trouble
cannot be performed.
rtion of ROM of U22 of MAIN circuit board.
INT memory write-in
Memory write-in of the head circuit board
Turn OFF the power switch and check whether
trouble
cannot be performed.
CN38 of MAIN circuit board is disconnected
or loose
(No display)
Abnormal power source
Power source voltage type is different.
Turn OFF the power switch and check the
Disconnection of connector
The connector is disconnected.
power source voltage and check whether
CN3 of FLT circuit board or CN13 of SDC
circuit board is disconnected or loose.
Indication
Name of error
Description of error
Corrective measure
Remarks
Содержание LK-1900A
Страница 20: ... 16 10 Hook adjustment Standard Adjustment 0mm 0mm 7 5mm 0 05 0 1mm For DPX5 For DPX17 ...
Страница 87: ... 83 Grease Grease 3 Thread tension area 4 Thread trimmer area Grease Juki Grease A Grease Grease Juki Grease A ...
Страница 88: ... 84 Grease Grease Grease Templex N2 Grease Templex N2 Grease Grease Grease Grease Grease 5 Feed area ...
Страница 90: ... 86 Grease Grease Grease Grease Grease 8 Needle thread clamp mechanism area ...
Страница 91: ... 87 Grease Grease A Grease Grease Grease Grease 9 LK 1901A relations ...
Страница 92: ... 88 10 LK 1903A relations Grease Grease ...
Страница 114: ... 111 12 Circuit diagrams 1 Block diagram A ...
Страница 115: ... 112 2 Power supply circuit diagram A ...
Страница 116: ... 113 3 Power supply circuit diagram B ...
Страница 117: ... 114 4 Power supply circuit diagram C ...
Страница 118: ... 115 5 Servo motor circuit diagram ...
Страница 119: ... 116 6 Sensor pedal VR circuit diagram ...
Страница 120: ... 117 7 MAIN PANEL board circuit diagram ...
Страница 121: ... 118 8 Motor solenoid circuit diagram Thread trimmer Lifting the work clamp foot motor ...