Field Configurators HARTConf, LHPConf for Transmitters with HART or LHP Communication and HART-USB Modem

1. General instructions and information

1.1 Symbols used

 

Symbol of warning; for safe use it is necessary

 

to proceed according to the instructions

 

Symbol CE certifies compliance of the product with 

 

the respective government directives

 

This product does not belong to public waste and it is

 

subjected to separate collection

HART

®

  Communication  protocol  for  reading  and  changes 

 

of configuration, registered trademark HART   

 

Communication Foundation

LHP

 

Remote communication for reading and changing    

 

of the configuration

1.2 Safety warnings and cautions

The  instrument  may  be  connected  only  to  the 
transmitters supplied from a safe source of voltage that 
meets  requirements  of  the  standard  EN  61010-1  and 

that are installed in compliance with the national requirements 
and  safety  standards. The  instrument  may  be  operated  only 
by a qualified person who has been familiar with this manual. 
The instrument may not be used for other purposes than as 
specified in this manual.
The maximum operational parameters of the instrument may 
not be exceeded to prevent any risk of injury from electric shock.
Use  the  instrument  in  a  suitable  environment,  without  direct 
sunlight,  dust,  high  temperature,  mechanical  vibrations  and 
surges; protect it against rain and excessive moisture.

1.3 Scope of delivery

With 

HARTConf 

is delivered:

 

- Cabel HART and cabel USB,

 

- CD with driver,

 

- Accumulator NiMH 8,4 V / 200 mA h,

 

- Instruction manual.

With 

LHPConf 

is delivered:

 

- Cabel HART,

 

- Battery 9 V 6LR61 (6F22),

 

- Instruction manual.

1.4 Description of the delivery and packing

The  product  is  packaged  in  a  protective  cover  and  provided 
with an identification label with a mark of the output control.
The product must not be exposed to direct rain, vibrations and 
shocks during transport.

1.5 Storage

The products shall be stored at temperatures from -20 °C to 
+40 °C and maximum relative humidity 80 % in the rooms with 
elimination of condensation of water vapours on the products.
The  stored  products  shall  not  be  exposed  to  any  shocks, 
vibrations and effects of harmful vapours and gases.

1.6 Installation and commissioning

During installation, commissioning, operation and maintenance 
follow the instructions in chapter 4.

1.7 Spare parts

Any of the compact parts of the product can be also ordered 
as a spare part if there are not required special procedures or 
technological operations for the exchange.

1.8 Repairs

Products  are  repaired  by  the  manufacturer. The  products  for 
repair  should  be  sent  in  a  packing  that  guarantees  damping 
of shocks and vibrations and protects against damage during 
transport.

1.9 Warranty

Products  are  covered  by  a  warranty  for  a  period  of  3  years 
from the delivery date on the delivery note. The manufacturer 
guarantees  technical  and  operational  parameters  of  the 
products  within  scope  of  the  applicable  documentation. 
Warranty period is specified with individual items and begins 
from  the  day  of  takeover  of  the  goods  by  the  purchaser  or 
delivery to the carrier. Any claims concerning to defects of the 
goods  together  can  be  filed  in  writing  with  the  manufacturer 
within  the  warranty  period  and  the  claimed  product  shall  be 
presented. The  claiming  party  shall  give  identification  of  the 
product,  number  of  the  delivery  note  and  description  of  the 
fault or defect.
The  manufacturer  is  not  responsible  for  any  defects  caused 
by  improper  storage,  incorrect  connection,  damages  caused 
by  external  effects,  in  particular  by  effects  of  factors  with 
excessive  values,  unqualified  installation,  improper  operation 
or common wearing.

2. End of service and disposal

2.1 End of service

Dismounting and disposal of the device is possible after
disconnecting of a battery.  

2.2 Disposal

When  disposing  the  packing  and  destroyed  or 
irreparably damaged product proceed according to the 
local regulations.

Содержание HARTConf

Страница 1: ...variables Testing a current loop and zero setting of a sensor Changing notes units damping etc Power supply for transmitter without any external power supply unit Configurator powering from an accumulator USB or a prismatic battery Up to 15 hours of continuous operation Using the instrument as a HART USB modem Language versions CZ EN DE RU or as required Accessories NL0899EN 2019 08 JSP s r o Indu...

Страница 2: ...and disposal 3 2 1 End of service 3 2 2 Disposal 3 3 Product description 4 3 1 Application 4 3 2 Functions of the HARTConf configurator 4 3 3 Functions of the LHPConf configurator 4 3 4 Dimensional drawings 4 3 5 Block diagram 5 4 Installation operation and maintenance 6 4 1 Installation and commissioning 6 4 2 Menu 7 4 3 Error messages 10 4 4 Operation and maintenance 11 5 Product specifications ...

Страница 3: ...ng transport 1 5 Storage The products shall be stored at temperatures from 20 C to 40 C and maximum relative humidity 80 in the rooms with elimination of condensation of water vapours on the products The stored products shall not be exposed to any shocks vibrations and effects of harmful vapours and gases 1 6 Installation and commissioning During installation commissioning operation and maintenanc...

Страница 4: ... can be set in HART USB Modem mode with suitable PC software software is not included with HARTConf It also includes all functions of a LHP configurator and it can therefore be used for the adjustment of all parameters of LHP transmitters It is supplied from a 9 V accumulator which can be charged from a USB port After connection to the USB port the configurator is supplied through this port which ...

Страница 5: ...ER HART HART LHP BATTERY Blokové schéma ručního konfigurátoru HARTConf MICROCOMPUTER KEYBOARD LHP DISPLAY POWER MANAGEMENT STEP UP DC POWER DC POWER LHP LHP BATTERY Blokové schéma ručního konfigurátoru LHPConf MICROCOMPUTER USB SERIAL KEYBOARD HART USB DISPLAY POWER MANAGEMENT DC DC DC AC DC POWER HART HART LHP BATTERY Blokové schéma ručního konfigurátoru HARTConf MICROCOMPUTER KEYBOARD LHP DISPLA...

Страница 6: ...sure that Battery Type is set to Accumulator If not set the switch correctly This ensures correct charging when the instrument is connected to USB 4 1 4 Installation of USB driver Correct work with a USB interface and charging through a USB requires the necessary USB driver installed on the PC Usually operating system search for a suitable driver after connecting the configurator to the USB port I...

Страница 7: ... s n Assembly No Units Trim DAC zero Trim DAC gain Device reset Sensor zeroing Polling addr Read Enter value Apply value OK Activate Terminate OK Manufacturer Model Burst mode Software rev Hardware rev Lower limit Upper limit Min span Assembly No Sensor s n Lower RV Upper RV Damping Date Tag Descriptor Message Transfer funct Unit Burst cmd Write protect Alarm signal Status Battery type Number form...

Страница 8: ...OFF Configurator HART Modem OK FW Update by Poll addr by Tag OK Int Ext Battery saver OK Read Enter value OK Editor handling Position change Symbol or number change OK Confirm or reject to save value Error Lower limit Upper limit Min span Message Assembly No Sensor s n Assembly No Units Trim DAC zero Trim DAC gain Device reset Sensor zeroing Polling addr Read Enter value Apply value OK Activate Te...

Страница 9: ...ardware rev Primary var Secondary var Tertiary var Fourth var Output current of range Lower RV Upper RV Damping Sensor input Sensor connect Compensation Date Tag Descriptor Alarm signal Write protect Fixed output Oper mode Disp refresh Number format Firmware Power supply OK OK OK OK OK OK OK Read Enter value Apply value OK Turn OFF OK Int Ext Battery saver OK Read Enter value OK Error Manufacturer...

Страница 10: ... Sensornummer Messanfang Messende Dämpfung Datum TAG Beschreibung Nachricht Übertr funktion Phys Einheiten Burst Befehl Schreibgeschützt Alarmart Status Batterietyp Zahlenformat Prim Batterie Akku OK Normal Erweitert OK Geräterevision Geräterevision Erweit Zustand Burst Sprache Löschen OK Sensornummer Übertr funktion Gerätenummer Long Tag Sensor PV OK Sensor PV Kompens TC Kompensation CVD Wert Ro ...

Страница 11: ...change Symbol or number change OK Confirm or reject to save value Ошибки Нижний предел Верхний предел Мин диапазон Сообщение сборки Серийный сборки Единицы Регулир 4 мА Регулир 20 мА Сброс устройства Обнуление датч Адрес опроса Читать Изменить Примен значен OK Включить Выключить OK Производитель Модель Пакет режим Версия ПО Аппарат верс Нижний предел Верхний предел Мин диапазон сборки Серийный Нач...

Страница 12: ...рвичная Вторичная Третья Четвертая Выходной ток диапазона Начало диапаз Конец диапаз Демпфирование Вход датчика Схема подкл Компенсация Дата Тег Дескриптор Авар сигнал Защита записи Фикс выход Режим работы Обновл дисп Формат номера Версия ПО Питание OK OK OK OK OK OK OK Читать Изменить Примен значен OK Выключить OK Внутр Внеш Энергосбережение OK Читать Изменить OK Ошибки Производитель Модель Идент...

Страница 13: ...he connected instrument does not support this command Service Menu of service functions Warning These functions are intended for advanced users only because they can cause a permanent change in parameters or adversely affect the calibration of the connected instrument Service Fixed Output It carries out output current loop test by the selected current After the current value is set and confirmed t...

Страница 14: ...fic device 4 3 Error messages The configurator saves up to 10 error messages or warnings that were sent to it from the connected instrument Some errors have more possible meanings according to the type of the instrument and desired activity The list of error messages together with the possible explanations Invalid selection incorrect combination of parameters Too large the value is too big Too sma...

Страница 15: ... 65 x 32 mm Material of case Black ABS Weight 85 g without battery Working position Arbitrary HART LHP interface Communication protocol HARTConf HART rev 5 LHP LHPConf LHP Transmitter supply voltage min 12 VSS 22 mA switch on switch off energy saving mode USB interface USB standard USB 1 1 Max power demand from USB interface With transmitter supply 140 mA Without transmitter supply 30 mA Battery c...

Страница 16: ...m and field handheld configurator for transmitters with HART and LHP communication function of transmitter supply supplied from USB or accumulator charged from USB Code Language 1 CZ Czech EN English DE German RU Russian Code Optional accessories only for HARTConf HARTWinConf PC configuration software HARTWinConf CZ EN WIN XP Vista 7 8 10 Example of order LHPConf ED Ex stock version 1 The language...

Страница 17: ...JSP s r o Raisova 547 506 01 Jičín Czech Republic 420 493 760 811 export jsp cz www jsp cz Your Supplier ...

Отзывы: