3-75
3
Note:
(1)
“Time”
area (example: 14:20-14:25) shows the starting time and stopping time of the call.
(2)
“Type of call”
shows the communication type and the direction as follows:
• Type
of
call
S&F:
Store & Forward communication (Telex communication)
S&F Poll:
Automatic response communication with S&F to the polling command
S&F sched:
Scheduled communication with S&F
S&F Dist:
Distress priority communication with S&F
Data RPT:
Data reporting
EDR:
Enhanced Data Reporting
EDR Sched:
Scheduled communication with EDR
EDR Prg:
Programmed Position Report with EDR
EDR Poll:
Immediate Position Report with EDR
EPADR:
Enhanced Pre-assigned Data Reporting
SLCA:
Slot Logical Channel Assignment (for EPADR)
SLCA Req:
SLCA Request
SLCA Ctrl:
SLCA Control (which is suspending SLCA or resuming SLCA)
EDR R-PADR: Re-sending data reporting by EDR which EPADR communication is failed
Distress: Distress
alerting
Log-in: Log-in
request
Log-out: Log-out
request
PV test:
Performance verification test
• Direction of call
R: Reception (Land subscriber to MES)
T: Transmission (MES to land subscriber)
(3)
“Msg no”
shows the serial number of the calls via each LES.
(4)
“Size”
shows number of characters in the message.
(5) 2nd line shows the result of the call.
Example)
Delivered to LES:
Message is transmitted to LES.
Delivered to subscriber :
Message is transmitted to (land) subscriber.
Reception success:
Message from LES is received.
Call failure:
Message transmission to LES or subscriber is
failed.
NOTE
“Delivered to LES” means the message you sent to land subscriber is received by LES as a relay point.
When you want to confirm whether the message is received by land subscriber, execution of “Delivery
confirmation request” is recommended.
When you turn ‘ON’ “delivery confirmation” function (see Fig. 3.8.1.) at the Telex window, you can
receive delivery confirmation automatically.
When you use
“Multi-address function”(
sending a message to up to 5 subscribers whom destination code
is same, via Telex), result of transmission is displayed individually. (checking
“Delivery confirmation
request”
window is not necessary).
Содержание jue-87
Страница 2: ......
Страница 11: ...v Type2 ...
Страница 24: ...xviii ...
Страница 30: ...1 2 ...
Страница 43: ...2 13 2 2 2 6 Coaxial Cable CFQ 5922A Connecting EME and Antenna Cable Fig 2 2 7 Coaxial Cable ...
Страница 45: ...2 15 2 2 3 2 JB2 Junction Box 2 NQE 3223 It is used when two or more RDB or EXT BUZ is installed Fig 2 3 2 JB2 ...
Страница 49: ...2 19 2 2 4 2 IME NTF 318 Fig 2 4 2 IME ...
Страница 50: ...2 20 2 4 3 DTE Keyboard NDF 369 Fig 2 4 3 DTE Keyboard Unit mm Mass 0 4kg ...
Страница 53: ...2 23 2 2 4 6 JB1 NQE 3222 Fig 2 4 6 JB1 ...
Страница 55: ...2 25 2 2 5 Dimensional Drawing Optional Components 2 5 1 RDB NQE 3225 Fig 2 5 1 Remote Distress Button ...
Страница 56: ...2 26 2 5 2 JB2 NQE 3223 Fig 2 5 2 JB2 ...
Страница 57: ...2 27 2 2 5 3 DTE Display NDZ 227 Keyboard NDF 369 Fig 2 5 3 DTE ...
Страница 58: ...2 28 2 5 4 EXT BUZ NCE 5547 Fig 2 5 4 EXT BUZ ...
Страница 59: ...2 29 2 2 5 6 SB Security Button NQE 3224 Fig 2 5 6 Security Button ...
Страница 60: ...2 30 ...
Страница 68: ...3 8 3 4 2 MES Status Area Fig 3 4 2 MES Status Area ...
Страница 155: ...3 95 3 Fig 3 13 3 1b Navarea Metarea ...
Страница 178: ...3 118 ...
Страница 198: ......
Страница 204: ...5 6 ...
Страница 206: ...A1 2 ...
Страница 210: ...A2 4 ...
Страница 218: ...A5 4 A5 3 Installation A5 3 1 Fix Tape Attachment ...
Страница 219: ...A5 5 ...
Страница 229: ......