6-32
Pulse timer settings Function
BTR 100P
Resulting SOG 100 pulses / NM
BTR 200P
Resulting SOG 200 pulses / NM (Default for Pulse timer F)
BTR 400P
Resulting SOG 400 pulses / NM
BTR 500P
Resulting SOG 500 pulses / NM
Table 3 Pulse timer settings
S15, SPD Average
S15 SPD AVERAGE
0 SEC
This menu will affect analogue and pulse outputs as well as those NMEA outputs programmed
for NMEA listeners “SPD ADPT”. Rapid changes of speed will be slowed down
by the set value in this menu. If, for example, this menu is set to 5 sec, it will take 5 seconds for
a speed change to be fully indicated on the output. When choosing this setting on an NMEA
output, speed is filtered according to the time setting but transmitted DPT is unchanged
S16, USB storage
S16 USB STORAGE
FILL UP
An USB memory stick can be used to store all received and transmitted NMEA messages in the
Sig. Distributor. This menu enables activation or deactivation of the NMEA storage. Please
reboot the Sig. Distributor before inserting USB memory stick. Average storage on USB
memory stick is approx. 300 MB/24h. Menu can be set to OFF, FILL UP or NFS. Use the FILL
UP option for USB storage. Use the NFS option for NFS-disk storage on the network. The
NFS-disk network address is set in the Sig. Distributor Web interface as AUTHORISED
EXPERT.
S17, USB Erase
S17 USB ERASE
DISABLED
This menu gives the possibility to completely erase and format an USB memory. However, it
might fail depending on Sig. Distributor load and the type of USB memory.
S18 – S19, IP-Addresses
S18 LPU2 ADDRESS
IP 192.168.5.17
Specifies the IP address of the Sig. Distributor. Last digit is default set to 17 and should
normally not be changed. As “authorized” it may be set from 1 to 50. If set outside this range, it
will use 1 or 50.
S19 SERVICE PC
IP 192.168.5.56
Содержание JLN-900
Страница 2: ......
Страница 12: ...x This page is intentionally blank ...
Страница 17: ...2 1 JLN 900 Technical Description ...
Страница 23: ...2 7 sigbel ...
Страница 30: ...2 14 This page is intentionally blank ...
Страница 31: ...3 1 JLN 900 Technical Specification ...
Страница 38: ...3 8 This page is intentionally blank ...
Страница 39: ...4 1 JLN 900 Installation of Transducer and Bottom Parts ...
Страница 49: ...4 11 Overall dimensions of the final installation is shown in Fig 1 2 Fig 1 2 MSSBSV H Main dimensions ...
Страница 59: ...4 21 Transducer and Valve Cover mounted Sea Valve fully opened ...
Страница 63: ...4 25 Fig 1 3 Aligning Transducer Connecting Tube ...
Страница 66: ...4 28 Overall dimensions of the final installation is shown in below Fig 2 2 Fig 2 2 MSDBSV H Main dimensions ...
Страница 76: ...4 38 Mounting Sea Valve on Upper Flange DB ...
Страница 81: ...4 43 Gasket Seal 2 ...
Страница 83: ...4 45 Transducer and Valve Cover mounted Sea Valve fully opened ...
Страница 86: ...4 48 Tube Bracket in its final position with Transducer flush seated ...
Страница 88: ...4 50 Fig 2 5 Aligning Transducer Connecting Tube ...
Страница 92: ...4 54 This page is intentionally blank ...
Страница 93: ...5 1 JLN 900 Installation of NJC 80 Sig Processor ...
Страница 101: ...6 1 JLN 900 NQA 4480 Sig Distributor Technical Manual Incl installation setting up and maintenance guidelines ...
Страница 150: ...6 50 This page is intentionally blank ...
Страница 151: ...7 1 JLN 900 Display Technical Description ...
Страница 167: ...7 17 No Name Default setting Function SD 4 2 SD 4 3 SD 4 4 there are remote systems connected ...
Страница 179: ...8 1 JLN 900 Analog Display Technical Manual ...
Страница 183: ...8 5 2 1 Main Dimensions NWW 828 Analog Display ...
Страница 184: ...8 6 2 2 Dimmer Potentiometer connection Analog Display ...
Страница 186: ...8 8 This page is intentionally blank ...
Страница 187: ...9 1 JLN 900 Menu System ...
Страница 208: ...9 22 This page is intentionally blank ...
Страница 209: ...10 1 JLN 900 WATER TRACK Technical Manual including Menu system ...
Страница 233: ...11 1 JLN 900 IEC 61162 NMEA 0183 User Guide ...
Страница 254: ...11 22 This page is intentionally blank ...
Страница 255: ...12 1 JLN 900 Harbour Acceptance Test ...
Страница 266: ...12 12 This page is intentionally blank ...
Страница 267: ...13 1 JLN 900 Calibration and Sea Acceptance Test ...
Страница 280: ...13 14 This page is intentionally blank ...
Страница 281: ...JLN 900 system drawings 14 1 ...
Страница 289: ...CFT 780 4 TRANSDUCER 40m 14 9 ...
Страница 290: ...NKF 980 Sea Valve 14 10 ...
Страница 291: ...NKF 980 Sea Valve 14 11 ...
Страница 292: ...NWW 82 MAIN DISPLAY 14 12 ...
Страница 293: ...DISPLAY 3 1 87 14 13 ...
Страница 294: ...NCM 1080 DIMMER UNIT 14 14 ...
Страница 295: ...15 1 JLN 900 Description labels and drawings ...
Страница 300: ...15 6 This page is intentionally blank ...
Страница 301: ...16 1 Annex JLN 900 Speed Log System Manual ...
Страница 302: ...16 2 Annex Table of contents ANNEX I EQUIPMENT RECYCLING 3 ANNEX II ENERGY SAVING 5 ...
Страница 306: ...16 6 This page is intentionally blank ...
Страница 307: ......