6-16
Connections to relays and opto coupler outputs
There are 16 outputs of this kind: 4 switching relays, 4 closing relays and 8 opto couplers. The
function of each relay/opto output can be programmed into the Sig. Distributor, using the
commands and procedures defined in section 5, "Setting up Procedure".
Note!
The switching relays K1-K4 are not intended for distance pulse function. First choice for
pulse function is opto O1-O8, second K5-K8. Warranty cannot be claimed if K1, K2, K3 or K4
are used for distance pulse function.
Switching relays
(NC=normally closed contact, CM=common, NO=normally open contact)
Relay# Term#
Default signal
K1
20:NC 20:CM
20:NO No NMEA Log 1 Main = de-energized
K2
21:NC 21:CM
21:NO No NMEA Log 1 Redundancy = de-energized
K3
22:NC
22:CM 22:NO
STW Astern = energized
K4
23:NC 23:CM
23:NO ESD Alarm = de-energized
When energized, the corresponding LED will be lit and CM-NO will be electrically connected.
In case of power fail of the Sig. Distributor, position NC-CM for the relays K1-K4 is valid.
The relays K1 and K2 supervise the NMEA in 1 and 5. The relays will be de-energized for no
NMEA activity.
Relay K3 will be energised when STW indicates astern speed.
Relay K4 will be de-energized when an Echo sounder alarm occurs ($SDALR,,,A,V,) until
acknowledged ($SDALR,,,A,A,).
Relay K4 can therefore be used as a contact for an external ESD buzzer.
If Opto in 1 is activated, K4 will be energized (external ESD buzzer mute).
If no ESD is connected to the Sig. Distributor the relay is de-energized.
Closing relays
(NO=normally open contact, CM=common)
Relay# Term#
Default signal
K5
24:CM 24:NO
Speed through water longitudinal 200p/nm, STW
K6
25:CM 25:NO
Speed through water longitudinal 200p/nm, STW
K7
26:CM 26:NO
Speed over ground resulting 200p/nm, BTR
K8
27:CM 27:NO
Speed over ground resulting 200p/nm, BTR
If no transversal SOG (BTT) is available, all BTR outputs will be calculated as if BTT=0, thus
BTR outputs will be equal to BTL. This is applicable for analogue out, pulse relays and opto-
couplers.
Содержание JLN-900
Страница 2: ......
Страница 12: ...x This page is intentionally blank ...
Страница 17: ...2 1 JLN 900 Technical Description ...
Страница 23: ...2 7 sigbel ...
Страница 30: ...2 14 This page is intentionally blank ...
Страница 31: ...3 1 JLN 900 Technical Specification ...
Страница 38: ...3 8 This page is intentionally blank ...
Страница 39: ...4 1 JLN 900 Installation of Transducer and Bottom Parts ...
Страница 49: ...4 11 Overall dimensions of the final installation is shown in Fig 1 2 Fig 1 2 MSSBSV H Main dimensions ...
Страница 59: ...4 21 Transducer and Valve Cover mounted Sea Valve fully opened ...
Страница 63: ...4 25 Fig 1 3 Aligning Transducer Connecting Tube ...
Страница 66: ...4 28 Overall dimensions of the final installation is shown in below Fig 2 2 Fig 2 2 MSDBSV H Main dimensions ...
Страница 76: ...4 38 Mounting Sea Valve on Upper Flange DB ...
Страница 81: ...4 43 Gasket Seal 2 ...
Страница 83: ...4 45 Transducer and Valve Cover mounted Sea Valve fully opened ...
Страница 86: ...4 48 Tube Bracket in its final position with Transducer flush seated ...
Страница 88: ...4 50 Fig 2 5 Aligning Transducer Connecting Tube ...
Страница 92: ...4 54 This page is intentionally blank ...
Страница 93: ...5 1 JLN 900 Installation of NJC 80 Sig Processor ...
Страница 101: ...6 1 JLN 900 NQA 4480 Sig Distributor Technical Manual Incl installation setting up and maintenance guidelines ...
Страница 150: ...6 50 This page is intentionally blank ...
Страница 151: ...7 1 JLN 900 Display Technical Description ...
Страница 167: ...7 17 No Name Default setting Function SD 4 2 SD 4 3 SD 4 4 there are remote systems connected ...
Страница 179: ...8 1 JLN 900 Analog Display Technical Manual ...
Страница 183: ...8 5 2 1 Main Dimensions NWW 828 Analog Display ...
Страница 184: ...8 6 2 2 Dimmer Potentiometer connection Analog Display ...
Страница 186: ...8 8 This page is intentionally blank ...
Страница 187: ...9 1 JLN 900 Menu System ...
Страница 208: ...9 22 This page is intentionally blank ...
Страница 209: ...10 1 JLN 900 WATER TRACK Technical Manual including Menu system ...
Страница 233: ...11 1 JLN 900 IEC 61162 NMEA 0183 User Guide ...
Страница 254: ...11 22 This page is intentionally blank ...
Страница 255: ...12 1 JLN 900 Harbour Acceptance Test ...
Страница 266: ...12 12 This page is intentionally blank ...
Страница 267: ...13 1 JLN 900 Calibration and Sea Acceptance Test ...
Страница 280: ...13 14 This page is intentionally blank ...
Страница 281: ...JLN 900 system drawings 14 1 ...
Страница 289: ...CFT 780 4 TRANSDUCER 40m 14 9 ...
Страница 290: ...NKF 980 Sea Valve 14 10 ...
Страница 291: ...NKF 980 Sea Valve 14 11 ...
Страница 292: ...NWW 82 MAIN DISPLAY 14 12 ...
Страница 293: ...DISPLAY 3 1 87 14 13 ...
Страница 294: ...NCM 1080 DIMMER UNIT 14 14 ...
Страница 295: ...15 1 JLN 900 Description labels and drawings ...
Страница 300: ...15 6 This page is intentionally blank ...
Страница 301: ...16 1 Annex JLN 900 Speed Log System Manual ...
Страница 302: ...16 2 Annex Table of contents ANNEX I EQUIPMENT RECYCLING 3 ANNEX II ENERGY SAVING 5 ...
Страница 306: ...16 6 This page is intentionally blank ...
Страница 307: ......