Centrum KD2 VR 

FUNCTIONING OF “JUNIOR 8” 

KEYPAD  

KEYPAD LEDS 

JR

 

 

Indicates the state of the panel 

 

Off 

Control panel disarmed 

 

On 

Control panel armed 

 

Flash each 2s  Control panel partially armed 

 

Blinking 

On Entry/Exit Path 

 

Bypass Led 

 Off 

No 

bypassed 

zone 

 

On 

There is a bypassed zone 

 Blinking  Unprogrammed 

clock 

 

Feeding LED 

 Off 

Correct 

Supply 

 

On 

Fail in Mains power (220Vac) 

 Blinking  Low 

Battery 

 

Alarm Memory Led 

 

Off 

No Alarm memory 

 

On 

There is Alarm memory 

 

Blinking 

Failure in zone. 

KEYPAD DISPLAY 

 

Appears when entering a wrong code or some 
erroneous function 

The display will also show the functions done, as well as 

several indications when entering the codes or 
programming. 

KEYPAD BUZZER 

The keypad has a buzzer that advice acoustically the 

control panel state when arming or carrying out some 
function. 
There are the following buzzer sounds: 
Entry path, Exit path, Day zone, Entry/exit zone (chime) 
detection, Intrusion alarm, Fire pre-alarm, Fire alarm, 
Keypad  tactile sound, Wrong code 
There are some sounds that can be deleted by 
programming ( entry/exit path) and more, through direct 
functions from the keypad ( chime and day zone).

 

PANEL IN STANDBY 

The Displays shows the state of the areas as: 

 
 | 

|  On 

Off 
 

Disarmed Area 
Armed Area 
 

 
Area 1 

Î

 

 

 

Í

 Area 2 

 

Zones Detection 

With the control panel disarmed, if there is some zone 
detection, the leds will show the detected zones. The 
corresponding led will light and will keep lit until restoring 

the zone (stop detecting). 

 

ARMING / DISARMING 

In order to arm/disarm de control panel, introduce a valid 
user code and then press E : 

User code 

+  E

 

= Changes panel state 

In case of having more than one area on the system, and 

in order to assure the arming / disarming of the user areas, 
use the absolute arming / disarming function just like: 

User Code 

+  F1

 

+  E  Always 

arms 

User Code 

+  F2

 

+  E  Always 

disarms 

After done, the display will show: 

 

Control panel arming 

 

Control panel disarming 

And next, the user number that has done the function. 

Nº User 

number 

 

If after disarming the system, any zone had caused 

alarm during the last arming period, the keypad will 
show these zones using Zone leds while the display will 

indicate: 

 

 

Also if there are zones in failure, these will be indicated 

after disarming while the displays shows: 

 

 

Also if there are outputs in failure, these will be 

indicated after disarming with numbers, while the 

keypad shows

:  

If when trying arming/disarming, if don’t allow, the display 
will show the cause. 

 

The Maid code can’t disarm because has 
exhausted its function 

 

 

The control panel can’t arm, because a priority 

zone is detecting at the moment of arming. 

 

 

Can’t arm/disarm by code because there is a 

latching key switch 

 

 

Lights to indicate that control panel is locked by 4 

wrong codes. 

CONTROL

 

PANEL

 IN ALARM 

When there is an alarm in the control panel, the display will 
blink: 

 

Control panel in alarm 

And the led of the zones will blink showing the zone/s that 
have caused the alarm. 

 

Will keep this state while the alarm last.(programmed time 

to the outputs). 

KEYS FUNCTIONS 

Содержание centrum KD2

Страница 1: ...User s Guide Ver 5 12 7...

Страница 2: ...duct and for trusting in our company This product fulfils all the security regulations it has overcome rigorous tests in process production and it is designed to offer you and your client the personal...

Страница 3: ...rry out using the Night arming and will arm the areas of the user that carries out the function and will bypass the zones programmed with the Night Arming bypass feature This is done by User code F1 E...

Страница 4: ...d detects the control panel will activate the output that has assigned and the phone communicator send the ambush report The keypad not show anything and the buzzer will not sound FIRE ALARM If there...

Страница 5: ...ce carried out the On and Off tones will be played indicating the state of the areas of the user code Activate Deactivate Outputs Press and then Output number the panel will reproduce the current stat...

Страница 6: ...t and will keep lit until restoring the zone stop detecting ARMING DISARMING In order to arm disarm de control panel introduce a valid user code and then press E User code E Changes panel state In cas...

Страница 7: ...ound F1 1 Police sends the police report to the central receiver F2 4 Fire sends the firemen report to the central receiver F3 7 Ambulance sends the medical assistance report to the central receiver F...

Страница 8: ...isplay will show If it s desired to store the programmed data press F1 If it s desired to modify the data enter the new data and press E USER CODES PROGRAMMING User code 1 001 1 1 1 1 User code 2 002...

Страница 9: ...deleted by programming entry exit path and more through direct functions from the keypad chime and day zone low bat of wireless detector PANEL IN STAND BY With PANEL disarmed the Display shows the sta...

Страница 10: ...eans that there are no more events to show Example Alarm in zone 9 25 of August at 12 45 0 9 1 2 4 5 2 5 0 8 4 Output Test activates the PANEL outputs during 2 seconds If is pressed before the keypad...

Страница 11: ...Master code from factory is 1111 After that the display will show It s not possible to access to user programming if PANEL is in Alarm Exit programming To exit programming press sequentially E The pa...

Страница 12: ...hange the telephone numbers for private call in case you change your mobile private number or telephone Company Private phone n 1 Example Tel 1 123456789 with dial tone detection 200 D 1 2 3 4 5 6 7 8...

Страница 13: ...BY When the panel is in standby the display shows the disarmed areas if any area is armed it won t be shown Each 8 seconds the keypad will show a sinoptic of the system State as Status Ta 14 0 C V 14...

Страница 14: ...5 produced events beginning with the most recent If no code is typed before pressing 3 the keypad will show a and the zones that have caused alarm during the last arming period The display shows the E...

Страница 15: ...vated To modify or remain the state press the suitable key F22S E Changes the State F1 Remain in same state Enabling disarming of the Maid code Press the code and press the function key User Code F32S...

Страница 16: ...5 PRIVATE PHONES PROGRAMMING In theses addresses you can change the telephone numbers for private call Private phone Ex Tel 1 1234567 with dial tone detection 200 D 1 2 3 4 5 6 7 F F E Private Phone 2...

Отзывы: