Centrum KD2
- 6 -
Centrum KD2 VR
FUNCTIONING OF “JUNIOR 8”
KEYPAD
KEYPAD LEDS
JR
Indicates the state of the panel
Off
Control panel disarmed
On
Control panel armed
Flash each 2s Control panel partially armed
Blinking
On Entry/Exit Path
Bypass Led
Off
No
bypassed
zone
On
There is a bypassed zone
Blinking Unprogrammed
clock
Feeding LED
Off
Correct
Supply
On
Fail in Mains power (220Vac)
Blinking Low
Battery
Alarm Memory Led
Off
No Alarm memory
On
There is Alarm memory
Blinking
Failure in zone.
KEYPAD DISPLAY
Appears when entering a wrong code or some
erroneous function
The display will also show the functions done, as well as
several indications when entering the codes or
programming.
KEYPAD BUZZER
The keypad has a buzzer that advice acoustically the
control panel state when arming or carrying out some
function.
There are the following buzzer sounds:
Entry path, Exit path, Day zone, Entry/exit zone (chime)
detection, Intrusion alarm, Fire pre-alarm, Fire alarm,
Keypad tactile sound, Wrong code
There are some sounds that can be deleted by
programming ( entry/exit path) and more, through direct
functions from the keypad ( chime and day zone).
PANEL IN STANDBY
The Displays shows the state of the areas as:
|
| On
Off
Disarmed Area
Armed Area
Area 1
Î
⎢
⎢
Í
Area 2
Zones Detection
With the control panel disarmed, if there is some zone
detection, the leds will show the detected zones. The
corresponding led will light and will keep lit until restoring
the zone (stop detecting).
ARMING / DISARMING
In order to arm/disarm de control panel, introduce a valid
user code and then press E :
User code
+ E
= Changes panel state
In case of having more than one area on the system, and
in order to assure the arming / disarming of the user areas,
use the absolute arming / disarming function just like:
User Code
+ F1
+ E Always
arms
User Code
+ F2
+ E Always
disarms
After done, the display will show:
Control panel arming
Control panel disarming
And next, the user number that has done the function.
Nº User
number
−
If after disarming the system, any zone had caused
alarm during the last arming period, the keypad will
show these zones using Zone leds while the display will
indicate:
−
Also if there are zones in failure, these will be indicated
after disarming while the displays shows:
−
Also if there are outputs in failure, these will be
indicated after disarming with numbers, while the
keypad shows
:
If when trying arming/disarming, if don’t allow, the display
will show the cause.
The Maid code can’t disarm because has
exhausted its function
The control panel can’t arm, because a priority
zone is detecting at the moment of arming.
Can’t arm/disarm by code because there is a
latching key switch
Lights to indicate that control panel is locked by 4
wrong codes.
CONTROL
PANEL
IN ALARM
When there is an alarm in the control panel, the display will
blink:
Control panel in alarm
And the led of the zones will blink showing the zone/s that
have caused the alarm.
Will keep this state while the alarm last.(programmed time
to the outputs).
KEYS FUNCTIONS
Содержание centrum KD2